EiceDRIVERTM SIL
1EDI2004AS
Specification
Table 56 Switching Characteristics (cont’d)
Parameter
Symbol
Values
Unit Note or Test Condition
Min. Typ. Max.
TTOFF (Regular) Plateau Time
tTTOFF 2.0
2.22 2.54 μs SRTTOF.RTVAL=26H, assuming
no TCF.
Gate Voltage Threshold 1 (low)
Gate Voltage Threshold 1 (high)
Gate Voltage Threshold 2 (high)
Gate Voltage Threshold 2 (low)
Active Clamping Activation Time
VGATE1L +1.95 +2.1 +2.25 V
VGATE1H +2.6 +3.0 +3.3 V
VGATE2H -3.3 -3.15 -3
V
VGATE2L -4.35 -4.2 -3.5 V
tACL
1.9 2.22 2.7 μs
Measured at pin GATE,
Referenced to VEE2, TJ= 150°C,
TCOEF= 1mV/K5)
Measured at pin GATE,
Referenced to VEE2, TJ= 150°C,
TCOEF= -2.6mV/K5)
Measured at pin GATE,
Referenced to VCC2, TJ= 150°C,
TCOEF= -1mV/K5)
Measured at pin GATE,
Referenced to VCC2, TJ= 150°C,
TCOEF= 2mV/K5)
Default value of bit field
SACLT.AT.6)
WTO Level
VGPON0 8.0 9.0 10.0 V Referenced to GND2, measured
at pin TON (shorted with TOFF)
VCC2=typ.,TJUNC=25°C, no VBE
Comp. 4)
WTO Level
VGPON0 8.7 9.7 10.7 V Referenced to GND2, measured
at pin TON (shorted with TOFF)
VCC2=typ.,TJUNC=25°C, with VBE
Comp. 4)
1) Valid for single switching events with SCFG.AMCLD and SRTTOF.RTVAL set to 0. Other settings will extend the timing
for regular turn on/off by configured SCFG.AMCLD or SRTTOF.RTVAL value.
2) Valid for single switching events with SCFG.AMCLD set to 0. Other settings will extend the timing for regular turn
on/off by configured SCFG.AMCLD value.
3) Not subject to production test. Parameters are verified by design / characterization.
4) Preliminary data need to be justified by characterization.
5) For other temperatures the temperature coefficent TCOEF applies [formula: V = V @ TREF + (T-TREF)*TCOEF].
6) If a following switching sequence occure during this time the delay will extend.
Data Sheet
131
Rev. 2.0
2019-01-16