Power Up Sequence (Commands Required)
Command Required
POR Status
Set External / Internal Oscillator
Set Voltage Tripler / Doubler
Internal DC/DC Converter Enable
Set Internal Regulator On
Set Temperature Coefficient
Set Internal Contrast Control On
Set Contrast Level
Set Internal Voltage Divider On
Set Column Mapping
Set Row Mapping
Set Vertical Scroll Value
Set Oscillator Enable
Set Annunciator Control Signals
Master Clear RAM
Dummy Write Data
Set Display On
External
Tripler
Off
Off
TC=0%
Off
Contrast Level = 0
Off
Seg. 0 = Col. 0
Com. 0 = Row 0
Scroll Value = 0
Disable
All Annunciators off
Random
Off
Remarks
*1
*1
*1
*1
*1, *3
*1, *3
*1, *2, *3
*1
*1
*1
*1
*1
Remarks :
*1 -- Required only if desired status differ from POR.
*2 -- Effective only if Internal Contrast Control is enabled.
*3 -- Effective only if Regulator is enabled.
Display Output Description by Example
This an example of output pattern on the LCD panel. Figure 8a, 8b and 8c are
data map of GDDRAM and the output pattern on the LCD display with different
command enabled. (Scrolling, Column Re-map and Row Re-map)
COM0
COM16
SEG0
Figure 8a
SEG119
Content of GDDRAM
PAGE 1
5A5A5A---000000
5A5A5A---000000
PAGE 2
33CC33---CC33CC
33CC33---CC33CC
Figure 8b
Graphic Mode
Column remap disable
Row remap disable
Graphic Mode
Column remap enable
Row remap disable
Graphic Mode
Column remap disable
Row remap enable
Figure 8c
MOTOROLA
Graphic Mode
Column remap disable
Row remap disable
Scroll Value = 0FH
MC141537