Electrical specification
STLC3085
Table 5. Electrical characteristics (continued)
Test conditions: Vpos = 6.0V, AGND = BGND, Normal Polarity, Tamb = 25°C.
External components as listed in the "Typical Values" column of EXTERNAL COMPONENTS Table.
Note: Testing of all parameter is performed at 25°C. Characterisation as well as design rules used allow correlation of
tested performances at other temperatures. All parameters listed here are met in the operating range: -40 to +85°C.
Symbol
Parameter
Test Condition
Min. Typ. Max. Unit
Iih
Input high current
Iil
Input low current
Vol Output low voltage
Iol = 1mA
-10
10
µA
-10
10
µA
0.45
V
PSRR AND POWER CONSUMPTION
PSERRC
Power supply rejection Vpos to Vripple = 100mVrms
2W port
50 to 4000Hz
Ivpos
Vpos supply current @ ii = 0
HI-Z On-Hook
ACTIVE On-Hook,
RING (line open)
Ipk (3)
RING Off-Hook
Peak current limiting accuracy RSENSE = 130mΩ
26
36
dB
13
25
mA
50
80
mA
55
90
mA
-20% 770 +20% mApk
(1) RL: Line Resistance
(2) Rlrt = Maximum loop resistance (incl. telephone) for correct ring trip detection.
(3) Buck Boost configuration.
10/28