50 500 5k 50k 100k 500k 5M 25M 50M
FREQUENCY – Hz
Figure 8. Temperature Error vs. Differential-Mode Noise
Frequency
ADM1021
100
ADDX = HI-Z
80
60
40
ADDX = GND
20
0
–20
0 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5 2.7 2.9 3.5 4.5
SUPPLY VOLTAGE – Volts
Figure 10. Standby Supply Current vs. Supply Voltage
200
180
160
140
120
100
80
VCC = +5V
60
VCC = +3.3V
40
20
0
0.0625 0.125 0.25
0.5
1
2
4
8
CONVERSION RATE – Hz
Figure 9. Operating Supply Current vs. Conversion
Rate
125
100
75
50
IMMERSED
25
IN +115؇C
FLUORINERT BATH
0
T=0
T=2
T=4
T=6
T=8
T = 10
TIME – Sec
Figure 11. Response to Thermal Shock
FUNCTIONAL DESCRIPTION
The ADM1021 contains a two-channel A-to-D converter with
special input-signal conditioning to enable operation with remote
and on-chip diode temperature sensors. When the ADM1021 is
operating normally, the A-to-D converter operates in a free-
running mode. The analog input multiplexer alternately selects
either the on-chip temperature sensor to measure its local tem-
perature, or the remote temperature sensor. These signals are
digitized by the ADC and the results stored in the Local and
Remote Temperature Value Registers as 8-bit, twos complement
words.
The measurement results are compared with Local and Remote,
High and Low Temperature Limits, stored in four on-chip regis-
ters. Out-of-limit comparisons generate flags that are stored in
the status register, and one or more out-of-limit results will
cause the ALERT output to pull low.
The limit registers can be programmed, and the device con-
trolled and configured, via the serial System Management Bus.
The contents of any register can also be read back via the SMBus.
Control and configuration functions consist of:
• Switching the device between normal operation and standby
mode.
• Masking or enabling the ALERT output.
• Selecting the conversion rate.
MEASUREMENT METHOD
A simple method of measuring temperature is to exploit the
negative temperature coefficient of a diode, or the base-emitter
voltage of a transistor, operated at constant current. Unfortu-
nately, this technique requires calibration to null out the effect
of the absolute value of Vbe, which varies from device to device.
The technique used in the ADM1021 is to measure the change
in Vbe when the device is operated at two different currents.
This is given by:
where:
Vbe = KT/q × ln (N)
K is Boltzmann’s constant
q is charge on the electron (1.6 x 10–19 Coulombs)
T is absolute temperature in Kelvins
N is ratio of the two currents
REV. 0
–5–