C3 SCSP Flash Memory
5.2
Operating Conditions
Table 10.
Maximum Operating Conditions
Symbol
Parameter
Notes
Min
Max
Units
TCASE
VCC / VCCQ
Operating Temperature
F-VCC /F-VCCQ /S-VCC Supply
Voltage
–25
+85
°C
1
2.7
3.3
Volts
VPP1
VPP2
Cycling
Supply Voltage
Block Erase Cycling
1
1.65
3.3
1, 2
11.4
12.6
2
100,000
Volts
Volts
Cycles
Notes:
1.
F-VCC/F-VCCQ must share the same supply. F-VCC/S-VCC must share the same supply when not in
data retention.
2.
Applying F-VPP = 11.4 V–12.6 V during a program/erase can only be done for a maximum of 1000
cycles on the main blocks and 2500 cycles on the parameter blocks. F-VPP may be connected to 12 V
for a total of 80 hours maximum. See Section 4.2.1 for details.
5.3
Table 11.
Capacitance
TCASE = +25°C, f = 1 MHz
Capacitance
Sym
Parameter
Notes Typ
CIN
Input Capacitance
1
16
COUT Output Capacitance
1
20
Note: Sampled, not 100% tested.
Max
18
22
Units
Conditions
pF
VIN = 0 V
pF
VOUT = 0 V
Datasheet
Intel® Advanced+ Boot Block Flash Memory (C3) SCSP Family
Order Number: 252636, Revision: 004
26 Aug 2005
27