DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PM9110BFA Ver la hoja de datos (PDF) - South African Micro Electronic Systems

Número de pieza
componentes Descripción
Fabricante
PM9110BFA
Sames
South African Micro Electronic Systems Sames
PM9110BFA Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
PM9110BF
The values of these resistors should be calculated as follows:
Phase 1:
R8 = R9 = (IL1/16mA) * R18/2
Phase 2:
R10 = R11 = (IL2/16mA) * R19/2
Phase 3:
R12 = R13 = (IL3/16mA) * R20/2
Where ILX = Secondary CT current at rated conditions.
R18, R19 and R20 =
Termination resistors of the three current transformers.
R1A+ R1B, R4 and R15 set the current for the phase 1 voltage sense input. R2A + R2B,
R5+ P5 and R16 set the current for phase 2 and R3A+ R3B, R6+ P6 and R17 set the current
for phase 3. The values should be selected so that the input currents into the voltage
sense inputs (virtual ground) are set to
C1, C2 and C3 are for decoupling and
1p4hmasAeRMcSofmorpreantseadtiloinne.
voltage.
Capacitors
Rco7nddietifoinnessaarell
on-chip bias and
set. Any changes
reference currents.
to R7 will affect the
With
output
qRu7a=dr2a4tikcal,lyo(pi.teim: umR
= +5%, f = +10%).
XTAL is a colour burst TV crystal (f = 3.5795MHz) for the oscillator. The oscillator
frequency is divided down to 1.7897MHz on-chip and supplies the A/D converters
and the digital circuitry.
10. Demonstration Software
Serial communication with the SA9110A device is identical to the communication
found on the Single Phase family member, SA9109A. For this reason the
demonstration software for the Single Phase Application circuit is used for the Three
Phase Application.
The software package which accompanies the demonstration unit requires an IBM
or compatible PC with MS-DOS installed. This software, supplied on a 1.44M 3½"
disk, will allow the user to read and write settings from/to the demonstration unit.
Ensure that the communication connectors are in place prior to start.
Insert the diskette into the drive and at the DOS prompt, type A:SA9109 [enter]
Context sensitive help screen for each input field or command prompt are available
by invoking [alt] H or [F1] key.
An introduction is available by pressing the [F1] key immediately after installation.
sames
7/14

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]