LT4356-3
APPLICATIONS INFORMATION
Fault Timer Current
The timer current starts at around 2µA with 0.5V or less
of VDS, increasing linearly to 50µA with 75V of VDS dur-
ing an overvoltage fault (Figure 1). During an overcurrent
fault, it starts at 4µA with 0.5V or less of VDS but increases
to 260µA with 80V across the MOSFET (Figure 2). This
arrangement allows the pass transistor to turn off faster
during an overcurrent event, since more power is dissipated
during this condition. Refer to the Typical Performance
Characteristics section for the timer current at different
VDS in both overvoltage and overcurrent events.
VTMR(V)
1.35
1.25
ITMR = 5µA
VDS = 75V
(ITMR = 50µA)
When the voltage at the TMR pin, VTMR, reaches the 1.25V
threshold, the FLT pin pulls low to indicate the detection
of a fault condition and provide warning to the load of
the impending power loss. In the case of an overvoltage
fault, the timer current then switches to a fixed 5µA. The
interval between FLT asserting low and the MOSFET turn-
ing off is given by:
t WARNING
=
CTMR 100mV
5µA
ITMR = 5µA
VDS = 10V
(ITMR = 8µA)
0.50
tFLT
= 15ms/µF
tWARNING
= 20ms/µF
tFLT = 93.75ms/µF
TOTAL FAULT TIMER = tFLT + tWARNING
tWARNING
= 20ms/µF
Figure 1. Overvoltage Fault Timer Current
TIME
43563 F01
VTMR(V)
1.35
1.25
VDS = 80V
(ITMR = 260µA)
VDS = 10V
(ITMR = 35µA)
0.50
tFLT
= 2.88ms/µF
tWARNING
= 0.38ms/µF
tFLT = 21.43ms/µF
TOTAL FAULT TIMER = tFLT + tWARNING
tWARNING
= 2.86ms/µF
Figure 2. Overcurrent Fault Timer Current
TIME
43563 F02
43563fb
11