TSL2580, TSL2581
LIGHT-TO-DIGITAL CONVERTER
TAOS098 − MARCH 2010
When INTR = 11, the interrupt is generated immediately following the SMBus write operation. Operation then
behaves in an SMB-Alert mode, and the software set interrupt may be cleared by an SMB-Alert cycle.
Note: Interrupts are based on the value of Channel 0 only.
Table 6. Interrupt Control Register
Bit : 7
6
5
4
3
2
1
0
Address
02h
Resv INTR_STOP
INTR
PERSIST
Reset
00h
lid FIELD
Resv
a INTR_STOP
v INTR
ill PERSIST
BITS
7
6
5:4
3:0
DESCRIPTION
Reserved. Write as 0.
Stop ADC integration on interrupt. When high, ADC integration will stop once an interrupt is asserted. To
resume operation (1) de-assert ADC_EN using CONTROL register, (2) clear interrupt using COMMAND
register, and (3) re-assert ADC_EN using CONTROL register. Note: Use this bit to isolate a particular
condition when the sensor is continuously integrating.
INTR Control Select. This field determines mode of interrupt logic according to Table 7, below.
Interrupt persistence. Controls rate of interrupts to the host processor as shown in Table 8, below.
t Table 7. Interrupt Control Select
G s INTR FIELD VALUE
00
A t 01
10
s n 11
READ VALUE
Interrupt output disabled
Level Interrupt
SMBAlert compliant
Test Mode: Sets interrupt and functions as mode 10
e NOTE: Field value of 11 may be used to test interrupt connectivity in a system or to assist in debugging interrupt service routine software.
m t Table 8. Interrupt Persistence Select
a n PERSIST FIELD VALUE
o 0000
0001
c 0010
l 0011
0100
a 0101
ic0110
0111
1000
n1001
1010
h 1011
c 1100
1101
e 1110
T 1111
INTERRUPT PERSIST FUNCTION
Every ADC cycle generates interrupt
Any value outside of threshold range
2 integration time periods out of range
3 integration time periods out of range
4 integration time periods out of range
5 integration time periods out of range
6 integration time periods out of range
7 integration time periods out of range
8 integration time periods out of range
9 integration time periods out of range
10 integration time periods out of range
11 integration time periods out of range
12 integration time periods out of range
13 integration time periods out of range
14 integration time periods out of range
15 integration time periods out of range
The LUMENOLOGY r Company
r
r
www.taosinc.com
Copyright E 2010, TAOS Inc.