DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

GCU08AA-130 Ver la hoja de datos (PDF) - MITSUBISHI ELECTRIC

Número de pieza
componentes Descripción
Fabricante
GCU08AA-130 Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
MITSUBISHI GATE COMMUTATED TURN-OFF THYRISTOR UNIT
GCU08AA-130
HIGH POWER INVERTER USE
PRESS PACK TYPE
Note 1. (1) Guaranteed power supply voltage for operation is 19V minimum and 21V maximum.
(2) When over voltage occurs, GDU voltage bus (G-K voltage for GCT) is clamped to be 21V if mamimum voltage for input gata voltage from power
supply is 25V and maximum duration of over voltage higher than 21V from power supply is 0.4 sec when control signal is on (Please see Fig. 8).
(3) When over voltage occurs, GDU voltage bus is clamped to be 21V with no time limitation if maximum voltage from power supply is 25V and control
signal is off (Please see Fig. 8).
Note 2. GCT is off state and no gate signal is supplied for gate driver. No leakage current flows between gate and cathode of GCT.
Note 3. Optic fiber data link HFBR-1521 and HFBR-2521 are interlocked each other.
Note 4.
1. Status signal from LED
(1) Status signal
Status of GCT
On state
Off state
LED 1
(Red)
OFF
ON
LED 2
(Yellow)
ON
OFF
(2) Fault signal
Status
Normal
Fault
Fault
Fault
G-K
Normal
Normal
G-K short
G-K short
PS
20±1V
Voltage down
20±1V
Voltage down
PS LED
(LED 4)
On
Off, V < 17.5V (Typ.)
On
Off, V < 17.5V (Typ.)
G-K LED
(LED 3)
On
Off (If V > 12.5V (Typ.) then LED 3 is on)
Off
Off
2. Status signal from Transmitter (Note 5)
(1) Normal operation
Control signal
(Control board)
Control signal
(GDU input)
L
NL
L
NL
Status signal
(GDU output)
L
NL
(L : Light NL : No light)
(2) Fault signal (O/V or U/V)
Control signal
(Control board)
Control signal
(GDU input)
Status signal
(GDU output)
L
NL
L
NL
L
L
NL
Normal
Fault
(3) Fault signal (G-K short)
Control signal
(Control board)
Control signal
(GDU input)
Status signal
(GDU output)
NL
NL
L
Normal
L
L
NL
Fault
Note 5. About over voltage fault signal, please see Fig. 6.
(3) Fault signal (fiber optic)
Control signal
(Control board)
L
NL
Control signal
(GDU input)
NL
L
Status signal
(GDU output)
(Always No light)
(Always light)
Mar. 2002