AP1694AEV10 User Guide
120VAC Triac Dimmable GU10 LED Driver
DIODES TAPPED TRANSFORMER DESIGN
AP1694A 120VAC Buck tapped 12V 400mA Transformer Spec
1) Bobbin
EEP10 4+4 pin
1
WD2: Primary
30#*1, 50Ts
6
6
WD1: P r i m a r y
34#*1, 74Ts
2
WD3: Auxiliary 36#1, 86Ts
7
5
2) Transformer Parameters
1. Primary Inductance (Pin1‐Pin7, all other windings are open)
Lp = 0.6mH ±5%@1kHz
2. Primary Winding Turns: NP=74Ts(Pin7‐Pin6) +50Ts(Pin6toPin1)
3. Auxiliary Winding Turns (Pin2‐ Pin5): NA= 86Ts (Pin 2 to Pin 5)
3) Transformer Winding Construction Diagram
Winding
Number
1
2
3
4
Windings
WD1‐Primary
Winding
WD2‐Primary
Winding
Insulation
WD3‐Auxiliary
Winding
Insulation
Winding
Specification
Start at Pin 7, wind 74 turns of single Φ34# wire and finish on Pin 6.
Start at Pin 6, wind 50 turns of single Φ30# wire and finish on Pin 1.
2 Layers of insulation tape
Start at Pin 2, wind 86 turns of single Φ36# wire and finish on Pin 5.
2 Layers of insulation tape
AP1694AEV10 Rev2
July 2015
www.diodes.com
Page 3 of 10