HV5812
AC ELECTRICAL CHARACTERISTICS
Electrical Specifications: Over recommended operating conditions; TA = 25°C unless otherwise indicated.
Parameter
Sym. Min. Typ. Max. Unit
Conditions
Blanking to Output Delay
tPHL
— 2000 —
tPLH
— 1000 —
Output Fall Time
tr
— 1450 —
Output Rise Time
tf
—
650
—
Data Set-up Time
tSU
75
—
—
Data Hold Time
tH
75
—
—
Minimum Data Pulse Width
tPWD
150
—
—
Minimum Clock Pulse Width
tPWCLK 150
—
—
Minimum Time between Clock
Activation and Strobe
tCKS
300
—
—
Minimum Strobe Pulse Width
Typical Time between Strobe
Activation and Output
Transition
tPWS
100
—
—
tSTO
—
500
—
Maximum Clock Frequency
—
8
—
fCLK
—
5
—
ns CL = 30 pF, 50% to 50%, VDD=5V
ns CL = 30 pF, 90% to 10%, VDD = 5V
ns CL = 30 pF, 10% to 90%, VDD = 5V
ns See Timing Waveforms.
ns See Timing Waveforms.
ns See Timing Waveforms.
ns See Timing Waveforms.
ns See Timing Waveforms.
ns SeeTiming Waveforms.
ns See Timing Waveforms.
MHz
TJ = +25°C, VDD = 5V
TJ = +125°C, VDD = 5V
TEMPERATURE SPECIFICATIONS
Parameter
Sym. Min. Typ. Max. Unit
TEMPERATURE RANGE
Operating Junction Temperature TJ
–40
— +125 °C
Storage Temperature
TS
–55
— +150 °C
PACKAGE THERMAL RESISTANCE
28-lead PDIP
28-lead PLCC
28-lead SOW
JA
—
43
— °C/W
JA
—
48
— °C/W
JA
—
55
— °C/W
Conditions
DS20005629A-page 4
2016 Microchip Technology Inc.