Ordering Information
Part Number
Package Option
HV3418PG-G
80-Lead PQFP
-G denotes a lead (Pb)-free / RoHS compliant package
Packing
66/Tray
Pin Configuration
HV3418
Absolute Maximum Ratings
Parameter
Value
Supply voltage, VDD
Output voltage, VPP
Logic input levels
Ground current 1
-0.5V to +15V
VDD to +200V
-0.5V to VDD +0.5V
1.5A
High voltage supply current 1
1.3A
Continuous total power dissipation 2
1200mW
Operating temperature range
-40°C to +85°C
Storage temperature range
-65°C to +150°C
Absolute Maximum Ratings are those values beyond which damage to the
device may occur. Functional operation under these conditions is not implied.
Continuous operation of the device at the absolute rating level may affect
device reliability. All voltages are referenced to GND.
Notes:
1. Connection to all power and ground pads is required. Duty cycle is
limited by the total power dissipated in the package.
2. For operation above 25°C ambiant derate linearly to maximum
operating temperature at 20mW/°C.
80
1
80-Lead PQFP
(top view)
Product Marking
HV3418PG
LLLLLLLLLL
YYWW
CCCCCCCC AAA
L = Lot Number
YY = Year Sealed
WW = Week Sealed
C = Country of Origin
A = Assembler ID
= “Green” Packaging
80-Lead PQFP
Package may or may not include the following marks: Si or
Typical Thermal Resistance
Package
80-Lead PQFP
θja
37OC/W
Recommended Operating Conditions
Sym Parameter
Min
VDD
Logic supply voltage
VDD = 5.0V
VDD = 12V
VPP
High voltage supply
VIH
High-level input voltage
VIL
Low-level input voltage
TA
Operating free-air temperature
4.5
10.8
60
VDD - 0.9
0
-40
Power-up sequence should be the following:
1. Connect ground
2. Apply VDD
3. Set all inputs (Data, CLK, Enable, etc.) to a known state
4. Apply VPP
The VPP should not drop below VDD or float during operation.
Power-down sequence should be the reverse of the above.
Typ
5.0
12.0
-
-
-
-
Max
5.5
13.2
180
VDD
0.9
+85
Units
V
V
V
V
°C
Doc.# DSFP-HV3418