DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LC015A Ver la hoja de datos (PDF) - Unspecified

Número de pieza
componentes Descripción
Fabricante
LC015A Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
LC/LW010- and LC/LW015-Series Power Modules:
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W
Data Sheet
March 27, 2008
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Parameter
Device Symbol Min
Input Voltage:
Continuous
Transient (100 ms)
LC
VI
0
LW
VI
0
LW
VI, trans
0
Operating Case Temperature
All
(See Derating Curves, Figures 43—45.)
TC
–40
Storage Temperature
All
Tstg
–55
I/O Isolation
All
Typ
Max
50
80
100
105*
125
1500
* Maximum case temperature varies based on power dissipation. See derating curves, Figures 43—45, for details.
Unit
Vdc
Vdc
V
°C
°C
Vdc
Electrical Specifications
Table 1. Input Specifications
Parameter
Device Symbol Min
Typ
Max
Unit
Operating Input Voltage
LC
VI
18
LW
VI
36
Maximum Input Current
LC
II, max
(VI = 0 to VI, max; IO = IO, max; see Figures
LW
II, max
1—4.)
Inrush Transient
All
I2t
Input Reflected-ripple Current
All
II
(5 Hz to 20 MHz; 12 µH source imped-
ance; TA = 25 °C; see Figure 33.)
Input Ripple Rejection (100 Hz—120 Hz) All
24
36
Vdc
48
75
Vdc
1.6
A
800
mA
0.2
A2s
5
mAp-p
45
dB
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2
Lineage Power

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]