TO-5 Double-Balanced Mixer,
0.2 - 200 MHz
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Frequency Range
Conversion Loss
Test Conditions
RF, LO Ports
IF Port
Frequency
0.2 - 200
DC - 200
—
Isolation
LO to RF
0.2 - 50 MHz
50 - 200 MHz
LO to IF
0.2 - 50 MHz
50 - 200 MHz
RF to IF
0.2 - 50 MHz
50 - 200 MHz
DC Polarity
Negative
—
DC Offset
RF Input2
1 dB Compression
1 dB Desensitization
SSB Noise Figure
Within 1 dB of Conversion Loss
—
Max.
MAC-50
V3
Units
Min
Typ
Max
MHz
—
—
—
MHz
—
—
—
dB
—
—
6.0
dB
35
—
—
dB
25
—
—
dB
35
—
—
dB
25
—
—
dB
25
—
—
dB
20
—
—
—
—
—
—
mV
—
<1
—
dBm
—
+1
—
dBm
—
-3
—
—
—
—
—
1. All specifications apply when operated at +7 dBm available LO power with 50 ohm source and load impedance.
2. Measured at 100 MHz
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.