Philips Semiconductors
Frame Transfer CCD Image Sensor
Product specification
FT 18
Specifications
Absolute Maximum Ratings
GENERAL:
storage temperature
ambient temperature during operation
voltage between any two gates
DC current through any clock (absolute value)
OUT current (no short circuit protections)
VOLTAGES IN RELATION TO VNS:
VPS, SFS
SFD
RD
All other pins
VOLTAGES IN RELATION TO VPS:
VNS
SFD, RD
SFS
All other pins
VNS2
VPS
SFD
SFS
VCS
OG
RD
DC Conditions1
N substrate
P substrate
Source Follower Drain
Source Follower Source
Current Source
Output Gate
Reset Drain
Min.
-55
-40
-20
-0.2
0
-30
-8
-15
-32
-0.5
+0
-8
-20
Min.
16
2
18
-
-2
3
12
Max.
Unit
+80
°C
+60
°C
+20
V
+0.2
µA
6
mA
+0.5
V
+8
V
+0.5
V
+0.5
V
+30
V
+30
V
+8
V
+20
V
Typical
Max.
Unit
adjusted
24
V
4
6
V
20
22
V
0
-
V
0
3
V
5.4
8
V
13
15
V
AC Clock Level Conditions1
IMAGE CLOCKS:
A-clock swing
A-clock low level
Charge Reset (CR) level on A-clocks 3
Charge Pump (CP) level on A- clocks
STORAGE CLOCKS (duty cycle=5/8):
B-clock swing
B-clock low level
OUTPUT REGISTER CLOCKS (duty cycle=1/2):
C-clock swing
C-clock low level
Min.
9.5
-
-
-
9.5
-
-
-
Typical
Max.
Unit
10
-
V
0
-
V
-5
-
V
0
-
V
10
-
V
0
-
V
5
3
-
-
V
V
OTHER CLOCKS:
Reset Gate (RG) swing
Reset Gate (RG) low level
-
10
12
V
-
1
-
V
1 All voltages in relation to SFS.
2 To set the VNS voltage for optimal Vertical Anti-Blooming (VAB), it should be adjustable between minimum and maximum values.
3 Guaranteed charge reset requires the CR voltage to last at least 1.2µs.
2000 January