CMPWR280
Thresholds vs. Temperature. Threshold vs.
Temperature shows the regulator select/deselect threshold
variation up to the maximum rated junction temperature.
The overall 125C change in junction temperature causes
a 30 mV variation in the select threshold voltage (regulator
enable). The deselect threshold level varies about 30 mV
over the 125C change in junction temperature. This results
in the built−in hysteresis having minimal variation over the
entire operating junction temperature range.
Figure 21. Threshold vs. Temperature