DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

XE1414 Ver la hoja de datos (PDF) - Xecom

Número de pieza
componentes Descripción
Fabricante
XE1414 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
XE1414 Class 2 Fax Commands
+FCLASS=n - Set Service Class
n=0 Configured as a data modem
n=1 Configured for Service Class 1
n=2 Configured for Service Class 2
n=3 Reserved for Service Class 3
+FCLASS=? - Available Service Class
+FCLASS? - Current Service Class
+FAA=n - Adaptive Answer
n=0 Answer as selected Service Class
n=1 Answers as a data or fax modem.
+FBOR=n - T.4 Data Bit Order
n=0 Selects direct order for T.4 Data
n=1 Selects reverse order for T.4 data
+FBUF? - Buffer Size
+FCR=n - Capability to Receive
n=0 Do not pass message data to host
n=1 Pass message data to host
+FDCC = VR, BR, WD, LN, DF, ED, BF, ST -Set DCE
Capabilities Parameters
VR - Vertical Resolution
0 98 Lines Per Inch (Normal)
1 196 Lines Per Inch (Fine)
BR - Bit Rate
0 2400 bits per second
1 4800 bits per second
2 7200 bits per second
3 9600 bits per second
4 12,000 bits per second
5 14,400 bits per second
WD - Page Width
0 1728 pixels in 215 millimeters
1 2048 pixels in 255 millimeters
2 2432 pixels in 303 millimeters
LN - Page Length
0 297 millimeters
1 364 millimeters
2 unlimited
DF - Data Compression Format
0 1-D modified Huffman
1 2-D modified Read
ED - Error Correction
0 Disable Error Correction Mode
(Annex A of T.30)
BF - Binary File Transfer
0 Disable Binary File Transfer
1 Enable Binary File Transfer
ST - Scan Time per Line
Normal Resolution
0 0 milliseconds
1 5 milliseconds
2 10 milliseconds
3 10 milliseconds
4 20 milliseconds
5 20 milliseconds
6 40 milliseconds
7 40 milliseconds
Fine Resolution
0 milliseconds
5 milliseconds
5 milliseconds
10 milliseconds
10 milliseconds
20 milliseconds
20 milliseconds
40 milliseconds
+FAXERR - Fax Error Value
Code Disconnect Cause
0 Normal fax disconnect
1 Ring detected but handshake unsuccessful
2 Call terminated by the host
3 No telephone loop current
10 Phase A handshaking error
11 No answer, time out
20 Transmit Phase B error
21 Remote cannot receive or send
22 Command error transmit Phase B
23 Invalid command received
24 Response Errors
25 Local capabilites sent 3 times, no response
26 local capabilities not recognized
27 Failed to train at lowest speed
28 Invalid response received
40 T.4 transmit data error
43 No data from host
50 Transmit Phase D error
51 Invalid Response received in transmit Phase D
52 No response to next page message, 3
attempts
53 Invalid respone to the next page message
54 No response to End of Page message, 3
attempts
55 Invalid response to end of page message
56 No response to End of Mesage after 3
attempts
57 Invalid response to End of Message
58 Unable to continue after page interrupt
XECOM
(10)
XE1414

Share Link: 