LC75810E/T
Notes on the Power On and Power Off Sequences
The following sequences must be observed when power is turned on and off. (See Figure 3.)
• At power on: Logic block power supply (VDD) on → LCD driver block power supply (VLCD) on.
• At power off: LCD driver block power supply (VLCD) off → Logic block power supply (VDD) off.
However, if the logic and LCD driver block use a shared power supply, then the power supplies can be turned on and off at
the same time.
t1
VDD
t2
t3
VLCD
RES
Instruction execution
tWRES
VIL
VIH
Initial state settings
Display state
Display off
Display on
Display off
• t1 ≥ 0
• t2 > 0
• t3 ≥ 0 (t2 > t3)
• tWRES • • • 1μs min
“Display on/off control”
instruction execution
(Turning the display on)
“Display on/off control”
instruction execution
(Turning the display off)
Initial state setting
• Set display technique
• DCRAM data write
• ALATCH data write (If ALATCH is used)
• CGRAM data write (If CGRAM is used)
• Set AC and SC addresses
• Set display contrast (If the display contrast adjustment circuit is used)
Figure 3
No.7141-31/54