Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21661-RZ/-FR
Intellimod™ Module
Single-In-Line Intelligent Power Module
3 Amperes/600 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ. Max. Units
Control Sector
Supply Voltage
VD
Applied between VN1-VNC
13.5 15.0
VDB
Applied between VUFB-VUFS,
13.5 15.0
VVFB-VVFS, VWFB-VWFS
Circuit Current
ID
VD = 15V, VIN = 0V,
—
—
Total of VN1-VNC (U, V, W)
VD = 15V, VIN = 5V,
—
—
Total of VN1-VNC (U, V, W)
IDB
VDB = 15V, VIN = 0V,
—
—
VUFB-U(VUFS), VVFB-V(VVFS), VWFB-W(VWFS)
VDB = 15V, VIN = 5V,
—
—
VUFB-U(VUFS), VVFB-V(VVFS), VWFB-W(VWFS)
Fault Output Voltage
VFOH
VSC = 0V, FO Circuit: 1k Ω to 5V Pull-up
4.9
—
VFOL
VSC = 1V, IFO = -10mA
—
—
Input Current
IIN
VIN = 5V
0.70 1.06
PWM Input Frequency
fPWM
Tf ≤ 100°C, Tj ≤ 125°C
—
15
Short Circuit Trip Level*
VSC(ref)
Tj = 25°C, VD = 15V
0.43 0.48
Supply Circuit Under-voltage
UVDBt
Trip Level, Tj ≤ 125°C
10.0
—
UVDBr
Reset Level, Tj ≤ 125°C
10.5
—
UVDt
Trip Level, Tj ≤ 125°C
10.3
—
UVDr
Reset Level, Tj ≤ 125°C
10.8
—
Fault Output Pulse Width**
tFO
20
40
ON Threshold Voltage
Vth(on)
Applied between UP, VP, WP-VNC,
2.10 2.35
OFF Threshold Voltage
Vth(off)
UN, VN, WN-VNC
1.10 1.40
* Short Circuit protection is functioning only at the lower-arms. Please select the value of the external shunt resistor such that the SC trip level is less than 5.1A.
**FO signal is only asserted when the SC or UV protection is activated on the low side.
16.5
16.5
3.60
3.60
0.50
0.50
—
0.95
1.50
—
0.53
12.0
12.5
12.5
13.0
—
2.60
1.80
Volts
Volts
mA
mA
mA
mA
Volts
Volts
mA
kHz
Volts
Volts
Volts
Volts
Volts
µS
Volts
Volts
5