MBI5027
16-bit Constant Current LED Sink Driver with Error Detection
Electrical Characteristics
Characteristic
Symbol
Input
“H” level
VIH
Voltage
“L” level
VIL
Output Leakage Current
IOH
Output
Voltage
SDO
VOL
VOH
Output Current 1
IOUT1
Condition
Ta = -40~85ºC
Ta = -40~85ºC
VOH=17.0V
IOL=+1.0mA
IOH=-1.0mA
VDS=0.6V
Rext=720 Ω
Min. Typ. Max.
0.8VDD
-
VDD
GND
-
0.3VDD
-
-
0.5
-
-
0.4
4.6
-
-
Unit
V
V
μA
V
V
-
25.0
-
mA
Current Skew
dIOUT1
IOL=25mA
VDS=0.6V
Rext=720 Ω
-
±1
±3
%
Output Current 2
IOUT2
VDS=0.8V
Rext=360 Ω
-
50.0
-
mA
Current Skew
dIOUT2
IOL=50mA
VDS=0.8V
Rext=360 Ω
-
±1
±3
%
Output Current vs.
Output Voltage Regulation
%/dVDS
VDS within 1.0V and 3.0V
-
±0.1
-
%/V
Output Current vs.
Supply Voltage Regulation
%/dVDD
VDD within 4.5V and 5.5V
-
±1
-
%/V
Pull-up Resistor
Pull-down Resistor
RIN(up)
RIN(down)
OE (ED2)
LE(ED1)
250
500
800
KΩ
250
500
800
KΩ
VDS, Th1
When all output ports sink 20mA
simultaneously
1.0
-
-
V
Open Circuit Error***
VDS, Th2
When a single output port sinks
20mA
0.8
-
-
V
Discrimination Voltage
VDS, Th3
When all output ports sink 50mA
simultaneously
1.2
-
-
V
VDS, Th4
When a single output port sinks
50mA
1.0
-
-
V
IDD(off) 1 Rext=Open, OUT0 ~ OUT15 =Off
-
9
-
“OFF”
IDD(off) 2 Rext=720 Ω, OUT0 ~ OUT15 =Off
-
11
-
Supply
Current
IDD(off) 3 Rext=360 Ω, OUT0 ~ OUT15 =Off
-
14
-
mA
“ON”
IDD(on) 1 Rext=720 Ω, OUT0 ~ OUT15 =On
-
11
-
IDD(on) 2 Rext=360 Ω, OUT0 ~ OUT15 =On
-
14
-
*** To effectively detect the error occurring at the output port, MBI5027 has a built-in current detection
circuit. The current detection circuit will detect the effective current IOUT, , effective and compare the effective
current IOUT, , effective to the target current IOUT, target, defined by Rext. If IOUT, , effective is much less than the
target current IOUT, target, an error flag will be asserted in the built-in Shift Register. The minimum voltage
requirement for such current detection is VDS, Th1, VDS, Th2, VDS, Th3 and VDS, Th4.
-9-
April 2003, V0.8-4