DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MBM29F800BA-70PF Ver la hoja de datos (PDF) - Spansion Inc.

Número de pieza
componentes Descripción
Fabricante
MBM29F800BA-70PF
Spansion
Spansion Inc. Spansion
MBM29F800BA-70PF Datasheet PDF : 49 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MBM29F800TA-55/-70/-90/MBM29F800BA-55/-70/-90
MBM29F800TA/BA Command Definitions
Command
Sequence
Bus
Write
Cycles
First Bus
Write Cycle
Second
Bus
Write Cycle
Third Bus
Write Cycle
Fourth Bus
Read/Write
Cycle
Fifth Bus
Write Cycle
Sixth Bus
Write Cycle
Req'd Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data
Read/
Reset*1
Word
1 XXXh F0h — — — — — — — — — —
Byte
Read/
Reset*1
Word
555h
2AAh
555h
3
AAh
55h
F0h RA*2 RD*2 — — — —
Byte
AAAh
555h
AAAh
Word
555h
2AAh
555h
Autoselect
3
AAh
55h
90h IA*2 ID*2 — — — —
Byte
AAAh
555h
AAAh
Byte/Word
Program
Word
4
Byte
555h
2AAh
555h
AAh
55h
A0h PA
AAAh
555h
AAAh
PD
Word
555h
2AAh
555h
555h
2AAh
555h
Chip Erase
6
AAh
55h
80h
AAh
55h
10h
Byte
AAAh
555h
AAAh
AAAh
555h
AAAh
Word
555h
2AAh
555h
555h
2AAh
Sector Erase
6
AAh
55h
80h
AAh
55h SA 30h
Byte
AAAh
555h
AAAh
AAAh
555h
Sector Erase Suspend Erase can be suspended during sector erase with Addr (“H” or “L”). Data (B0h)
Sector Erase Resume
Erase can be resumed after suspend with Addr (“H” or “L”). Data (30h)
Notes : Address bits A11 to A18 = X = “H” or “L” for all address commands except or Program Address (PA) and
Sector Address (SA).
Bus operations are defined in “MBM29F800TA/BA User Bus Operation (BYTE = VIH)” and
“MBM29F800TA/BA User Bus Operation (BYTE = VIH)” in sDEVICE BUS OPERATION.
RA = Address of the memory location to be read.
IA = Autoselect read address.
PA = Address of the memory location to be programmed. Addresses are latched on the falling edge of
the WE pulse.
SA = Address of the sector to be erased. The combination of A18, A17, A16, A15, A14, A13, and A12 will
uniquely select any sector.
RD = Data read from location RA during read operation.
ID = Device code/manufacture code for the address located by IA.
PD = Data to be programmed at location PA. Data is latched on the rising edge of WE.
The system should generate the following address patterns:
Word Mode: 555h or 2AAh to addresses A10 to A0
Byte Mode: AAAh or 555h to addresses A10 to A-1
Both Read/Reset commands are functionally equivalent, resetting the device to the read mode.
Command combinations not described in Command Definitions table are illegal.
*1 : Both of these reset commands are equivalent.
*2 : The fourth bus cycle is only for read.
8

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]