DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MBM29LV800BA-120PFTR Ver la hoja de datos (PDF) - Fujitsu

Número de pieza
componentes Descripción
Fabricante
MBM29LV800BA-120PFTR
Fujitsu
Fujitsu Fujitsu
MBM29LV800BA-120PFTR Datasheet PDF : 59 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MBM29LV800TA-70/-90/-12/MBM29LV800BA-70/-90/-12
Table 8 MBM29LV800TA/BA Extended Command Definitions
Command
Sequence
Set to
Fast Mode
Fast
Program*1
Word
Byte
Word
Byte
Bus
Write
Cycles
Req'd
3
2
First Bus
Write Cycle
Addr Data
555H
AAAH
AAH
XXXH
A0H
XXXH
Second Bus
Write Cycle
Addr Data
2AAH
55H
555H
PA
PD
Third Bus
Write Cycle
Addr Data
555H
20H
AAAH
—
—
Fourth Bus
Read Cycle
Addr Data
—
—
—
—
Reset from Word
Fast Mode *1 Byte
2
XXXH
XXXH
90H
F0H*3
—
XXXH
XXXH
—
—
—
Extended
Word
Sector
Protect*2
4
XXXH 60H SPA 60H SPA 40H SPA
SD
Byte
SPA : Sector address to be protected. Set sector address (SA) and (A6, A1, A0) = (0, 1, 0).
SD : Sector protection verify data. Output 01H at protected sector addresses and output 00H at unprotected
sector addresses.
*1:This command is valid while Fast Mode.
*2:This command is valid while RESET=VID.
*3:This data "00H" is also acceptable.
Command Definitions
Device operations are selected by writing specific address and data sequences into the command register.
Writing incorrect address and data values or writing them in the improper sequence will reset the devices to the
read mode. Table 7 defines the valid register command sequences. Note that the Erase Suspend (B0H) and
Erase Resume (30H) commands are valid only while the Sector Erase operation is in progress. Moreover both
Read/Reset commands are functionally equivalent, resetting the device to the read mode. Please note that
commands are always written at DQ0 to DQ7 and DQ8 to DQ15 bits are ignored.
Read/Reset Command
In order to return from Autoselect mode or Exceeded Timing Limits (DQ5 = 1) to read/reset mode, the read/reset
operation is initiated by writing the Read/Reset command sequence into the command register. Microprocessor
read cycles retrieve array data from the memory. The devices remain enabled for reads until the command
register contents are altered.
The devices will automatically power-up in the read/reset state. In this case, a command sequence is not required
to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no
spurious alteration of the memory content occurs during the power transition. Refer to the AC Read
Characteristics and Waveforms for the specific timing parameters.
18

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]