DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MBM29LV800BA-120PFTR Ver la hoja de datos (PDF) - Fujitsu

Número de pieza
componentes Descripción
Fabricante
MBM29LV800BA-120PFTR
Fujitsu
Fujitsu Fujitsu
MBM29LV800BA-120PFTR Datasheet PDF : 59 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MBM29LV800TA-70/-90/-12/MBM29LV800BA-70/-90/-12
Table 7 MBM29LV800TA/800BA Standard Command Definitions
Command
Sequence
Bus
Write
Cycles
Req’d
First Bus Second Bus
Write Cycle Write Cycle
Addr. Data Addr. Data
Third Bus
Write Cycle
Addr. Data
Fourth Bus
Read/Write
Cycle
Addr. Data
Fifth Bus
Write Cycle
Addr. Data
Sixth Bus
Write Cycle
Addr. Data
Word
Read/Reset
1 XXXH F0H — — — — — — — — — —
Byte
Word
555H
2AAH
555H
Read/Reset
3
AAH
55H
F0H RA RD — — — —
Byte
AAAH
555H
AAAH
Word
555H
2AAH
555H
Autoselect
3
AAH
55H
90H — — — — — —
Byte
AAAH
555H
AAAH
Program
Word
555H
2AAH
555H
4
AAH
55H
A0H PA PD — — — —
Byte
AAAH
555H
AAAH
Word
Chip Erase
6
Byte
555H
2AAH
555H
555H
2AAH
555H
AAH
55H
80H
AAH
55H
10H
AAAH
555H
AAAH
AAAH
555H
AAAH
Word
Sector Erase
6
Byte
555H
2AAH
555H
555H
2AAH
AAH
55H
80H
AAH
55H SA 30H
AAAH
555H
AAAH
AAAH
555H
Sector Erase Suspend Erase can be suspended during sector erase with Addr. (“H” or “L”). Data (B0H)
Sector Erase Resume Erase can be resumed after suspend with Addr. (“H” or “L”). Data (30H)
Notes: 1. Address bits A11 to A18 = X = “H” or “L” for all address commands except or Program Address (PA) and
Sector Address (SA)
2. Bus operations are defined in Tables 2 and 3.
3. RA = Address of the memory location to be read
PA = Address of the memory location to be programmed
Addresses are latched on the falling edge of the WE pulse.
SA = Address of the sector to be erased. The combination of A18, A17, A16, A15, A14, A13, and A12 will
uniquely select any sector.
4. RD = Data read from location RA during read operation.
PD = Data to be programmed at location PA. Data is latched on the falling edge of WE.
5. The system should generate the following address patterns:
Word Mode: 555H or 2AAH to addresses A0 to A10
Byte Mode: AAAH or 555H to addresses A–1 and A0 to A10
6. Both Read/Reset commands are functionally equivalent, resetting the device to the read mode.
17

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]