DC/DC-Converter
Specifications - Continued
R2S & R2D
Series
Isolation Voltage
Rated Working Voltage
H-Suffix
(tested for 1 second)
(tested for 1 second)
(long term isolation)
1000VDC min.
3000VDC min.
see Application Notes
Isolation Capacitance
20pF min. / 115pF max.
Isolation Resistance
10 GΩ min.
Short Circuit Protection
P-Suffix
1 Second
Continuous
Operating Temperature Range (free air convection)
-40°C to +100°C (see Graph)
Storage Temperature Range
Reflow Temperature
Vapour Phase Process
-55°C to +125°C
ROHS compliant
245°C (30 sec), peak 255°C (5 sec) max.
(for more details see Application Notes)
230°C (90 sec) max.
Relative Humidity
Package Weight
Packing Quantity
R2S, R2S8
R2D, R2D10
R2S12, R2D12
R2S, R2S8
R2S12, R2D, R2D10, R2D12
All Types
95% RH
1.4g
1.6g
2.0g
39 pcs per Tube
33 pcs per tube
250 pcs per Reel
} MTBF (+25°C)
Detailed Information see
(+85°C) Application Notes chapter "MTBF"
Certifications
CB Test Report
Report: US/14402/UL
UL General Safety Report: E322406
CUL General Safety
EN General Safety
EN Medical Safety
using MIL-HDBK 217F
using MIL-HDBK 217F
886 x 103 hours
128 x 103 hours
UL 60950-1 1st Ed.
C22.2 No. 60950-1-03
EN-60950-1 2rd Ed.
EN-60601-1
Typical Characteristics
Efficiency / Load
100
0505
1205
R2S-xx05 80
60
40
2405
20
0
0% 20% 40% 60%
Total Output current (%)
80% 100%
Derating-Graph
(Ambient Temperature)
R2S-0505, R2D-0505
100
80
60 Safe Operating Area
40
20
0
-40
0
50
100
150
Operating Temperature °C 110
The derating graph is valid only for the shown part
numbers. The converters have been tested at full
load with 100°C ambient temperature and all
internal component temperatures are within limits.
However, Recom can only guarantee continuous
operation of up to +85°C to maintain the validity of
the UL certificates.
Deviation / Load
25.000
20.000
0505
1205
15.000
10.000
5.000
0.000
-5.000
2405
-10.000
0% 20% 40% 60% 80%
Total Output current (%)
100%
R2D-xx05
E-46
Efficiency / Load
100
1205
80
60
0505
40
2405
20
0
0% 20%
40% 60%
Total Output current (%)
80% 100%
REV: 3/2010
Deviation / Load
25.000
20.000
0505
1205
15.000
10.000
5.000
0.000
-5.000
2405
-10.000
0% 20% 40% 60% 80%
Total Output current (%)