M-Series General Specifications
Electrical
Mechanical
Maximum Voltage
Current Ratings
Auxiliary Switch Rating
Insulation Resistance
Dielectric Strength
Resistance, Impedance
Pulse Tolerance Curves
125/250 VAC 50/60 Hz, 80 VDC
(See Rating Tables.)
Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00 thru 15.0 in 1
amp increments, 18.0,
20.0, 25.0, 30.0. Other ratings avail-
able - see Ordering Scheme.
SPDT; 7A 250VAC, 7A (Res)
28VDC, 4A (Ind.) 28VDC, 0.25A
80VDC (Res) (silver contacts), 0.1A
125VAC (gold contacts).
Minimum of 100 Megohms at 500
VDC.
UL, CSA 1500V, 50/60 Hz for one
minute between all electrically isolat-
ed terminals. M-Series Circuit
Breakers comply with the 8mm
spacing and 3750 V 50/60Hz dielec-
tric requirements from hazardous
voltage to operator accessible sur-
faces, per Publications IEC 380,
435, 950, EN 60950 and VDE 0805.
Values from Line to Load Terminal -
based on Series Trip Circuit Breaker.
Endurance
Trip Free
Trip Indication
Physical
10,000 ON-OFF operations @ 6 per
minute with rated Current and
Voltage.
All M-Series Circuit Breakers will trip
on overload, even when actuator is
forcibly held in the ON position.
The actuator moves positively to the
OFF position when an overload
causes the circuit breaker to trip.
Number of Poles
1 or 2
Internal Circuit Configurations Series with or without Auxiliary
Switch.
Switch Only with or without Auxiliary
Switch.
Weight
Approximately 30 grams/pole
(Approximately 1.07 ounces/pole)
Standard Colors
See Ordering Scheme.
Environmental
Designed and tested in accordance with requirements of specifi-
cation MIL-PRF-55629 & MIL-STD-202 as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Cond. I. Instantaneous
curves tested at 80% of rated current.
Vibration
Withstands 0.060" excursion from 10-
55 Hz, and 10 Gs 55-500 Hz, at rated
current per Method 204C, Test
Condition A. Instantaneous curves
tested at 80% of rated current.
Moisture Resistance
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-98% RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature -40° C to +85° C
Chemical Resistance
Only the outside surfaces of the case
and the handles may be cleaned with
detergents or alcohol. Organic (hydro-
carbon based) solvents are not rec-
ommended because they attack plas-
tics. Caution should be taken when
solvents are used to clean and
remove flux from terminals. Lubricants
should not be introduced into the han-
dle/bushing openings.