MITSUBISHI DIGITAL ASSP
M66307SP/FP
LINE SCAN BUFFER with 16-BIT MPU BUS COMPATIBLE INPUTS
1. Register configuration
The M66307 has the command registers shown in Figure 4. The
mode register consists of a total of eight flags (F0-F7) and seven bits
(B0-B6). Each flag and bit are set to default values (=0) by reset
input.
There are some commands that do not have a register. These in-
clude the one line fixed data setting command, transmit repeat re-
quest command, and the stop command.
2. Command organization
The commands are broadly classified into four groups as shown in
Fig. 3. It shows the relationship between the three modes of the
M66307 (static, write and send modes) and the storable commands.
Group 1
Group 2
Group 3
Group 4
1 Initialization command
2 DREQ words setting command
3 Fixed beginning date length setting command
4 Output format setting command
5 Operation mode setting command
6 One line fixed data setting command
7 Transmit repeat request command
8 Stop command
Command
Group 1 Group 2 Group 3 Group 4
Mode
Static
5
Write
6
Send complete
(BUSY=“H”)
7
Send
Send
(BUSY=“L”)
Note : Command store is valid within
Fig. 3 Command store Map
Description of commands
Command Upper bit
name (D15~D12)
Contents
Initialization 1000
command
This command initializes the hardware setting of the system by selecting clock input and setting the specification for
the use of extension, specification for DREQ output, specification for fixed data output, and the logical polarity of “fixed
data.”
DREQ words 0111 When [N] is set, M66307 outputs a Low from the DREQ pin when setting the write mode. When [N+1] words are
setting command
written by the DMA controller (MPU), it outputs a High from the DREQ pin.
Fixed
beginning
data length
setting
command
Output format
setting command
Operation
mode
setting
command
0110
0100
0000
This command sets the length of fixed beginning data from 3 to 4,095. When [n] is set to the fixed beginning data
length setting register, “fixed data” is output from the DATA OUT pin each time the send mode is entered. When “fixed
data” for [n+1] bits is output, the M66307 starts outputting the data stored in memory. Clock output (CLK/φ OUT), the
clock for synchronization, is output even while fixed data is being output. Note that even when the output format is
LIFO, the data in the internal memory is output after outputting fixed data is completed.
This command sets the output format for LIFO or FIFO and for MSB first or LSB first.
This command is stored in the 4-bit (B3, B2, B1, B0) register shown in Figure 4. The write and send modes are set by
this register. The send mode setting command when an extended 32-bit system is used and the mode inverting
command when an extended toggle system is used are two-word commands. Store the second word after storing the
first word. B3 is a DREQ mask bit. If the write mode is set by setting B3=1 when in the DREQ mode (F4=1), the
M66307 does not output a Low from the DREQ pin. When in the DREQ mode, set B3=1 when setting the write mode
before storing the one line fixed data setting command. It is impossible to control mode inversion with this command
and extended toggle input (TOG) together.
One line fixed 0011
data setting
command
When this command is stored, you obtain the same effect as writing “fixed data” for the set number of words. When set
to the send mode, “fixed data” equivalent to [(fixed beginning data set value+1)+(one line fixed data setting word
value+1)x16] bits is output along with the sync clock (CLK/φ OUT).
Transmit 0010
repeat request
command
This command allows you to resend the same data that has already been sent. This command becomes executable
after transmission is completed. When using an extended system, store the second word of the operation mode
setting command following the transmit repeat request command.
Stop
command
1111
This command stops the operation of the M66307. This command is valid in all modes. It initializes all registers and
circuits except the initialization register, output format setting register, DREQ words setting register, and fixed begin-
ning data length register, thereby placing the M66307 into the static mode. In addition to stopping operation, this
command may be used when you want to store the commands that can only be valid in the static mode (e.g., group 1
and group 2 commands).
7