VNI4140K-32
6
Thermal management
Thermal management
The power dissipation in the IC is the main factor that sets the safe operating condition of
the device in the application. Therefore, it must be very carefully considered. Furthermore,
the available space on the PCB should be chosen considering the power dissipation.
Heatsinking can be achieved using copper on the PCB with proper area and thickness. Two
different protections have been implemented to guarantee safety of the device if it overheats
due to an overloaded condition or high environment temperature. The following flowchart
explains in detail this protection functionality.
Figure 5. Thermal behavior
Vin(i) = H
OUT(i) On
STAT(i) Off (H)
1)
NO
YES
Tj(i) > Ttsd
OUT(i) Off
STAT(i) On (L)
YES
NO
4)
Tc > Tcsd
YES
NO
Tc > Tcr
2)
NO
YES
Tj(i) > Tjr
3)
Doc ID022576 Rev 3