DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CF2-B0-22-620-43G-D Ver la hoja de datos (PDF) - Unspecified

Número de pieza
componentes Descripción
Fabricante
CF2-B0-22-620-43G-D
ETC
Unspecified ETC
CF2-B0-22-620-43G-D Datasheet PDF : 27 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
8 | C-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme
C
1
Series
A
2
Actuator
3
3
Poles
B
4
Circuit
0
5
Aux/Alarm
Switch
14
6
Frequency
& Delay
450
7
Current Rating
1
8
Terminal
2
9
Actuator
Color
1
10
Mounting/
Barriers
KG
11
12
Max. App. Agency
Rating
Approval
1 SERIES
C
2 ACTUATOR 1
A Handle, one per pole
B Handle, one per multipole unit
S Mid-Trip Handle, one per pole
T Mid-Trip Handle, one per pole & Alarm Switch
3 POLES 2
1 One
2 Two
3
Three
4 CIRCUIT
B Series Trip (Current)
5 AUXILIARY / ALARM SWITCH 3
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
42 4 50/60Hz Short, Hi-Inrush
44 4 50/60Hz Medium, Hi-Inrush
46 4 50/60Hz Long, Hi-Inrush
52 4 DC Short, Hi-Inrush
54 4 DC Medium, Hi-Inrush
56 4 DC Long, Hi-Inrush
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units.
B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum.
S: Handle moves to mid-position only upon electrical trip of the breaker.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip
of the breaker.
2 Standard multipole units have all poles identical except when specifying auxiliary
switch and/or mixed poles.
2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating
code C) applications, have all poles identical except when specifying auxiliary /
alarm switch which is normally supplied in extreme right pole per figure B. Terminal
barriers are required on all multipole breakers.
Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd
pole has the same construction as poles 1 & 2.
3 On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme
right pole.
VDE approval on auxiliary switch codes 2, 3 & 4 only.
Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit,
only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC,
and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit
breaker, is supplied from factory with common terminal of auxiliary / alarm switch
connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated
120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common
terminal connected to breaker line terminal. Consult factory for special catalog
number.
4 Available up to 50 amps maximum.
5 Current ratings 71 - 100 with VDE approvals are available up to two poles
maximum.
6 Terminal Codes 9 & C are not VDE approved.
7 Terminal Code 1 available to 60 amps maximum.
8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum.
9 Terminal Codes 3, 6 & 9 available to 100 amps maximum.
10 Terminal Code A available to 100 amps maximum.
11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles.
12 Barriers supplied on multi-pole units only.
7 CURRENT RATING (AMPERES)
CODE AMPERES
210 0.100
295 0.950
215 0.150
410 1.000
220 0.200
512 1.250
225 0.250
415 1.500
230 0.300
517 1.750
235 0.350
420 2.000
240 0.400
522 2.250
245 0.450
425 2.500
250 0.500
527 2.750
255 0.550
430 3.000
260 0.600
435 3.500
265 0.650
440 4.000
270 0.700
445 4.500
275 0.750
450 5.000
280 0.800
455 5.500
285 0.850
460 6.000
290 0.900
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
660 60.000
670 70.000
680 80.000
685 85.000
690 90.000
695 95.000
810 100.00
8 TERMINAL 6
1 7 Stud 10-32
2 8 Screw 10-32
3 9 Stud 1/4-20
4 8 Stud M5 x 0.8
5 8 Screw M5 x 0.8
69
Stud M6
99
7/16” Clip Terminal
A 10 Plug-In Stud
C 8 5/16” Clip Terminal
9 ACTUATOR COLOR & LEGEND 11
Actuator Color
ON-OFF Dual
White
B
1
Black
D
2
Red
G
3
Green
J
4
Blue
L
5
Yellow
N
6
Gray
Q
7
Orange
S
8
Legend Color
Black
White
White
White
White
Black
Black
Black
10 MOUNTING / BARRIERS
MOUNTING STYLE
Threaded Insert
1 6-32 x 0.195 inches
2 ISO M3 x 5mm
BARRIERS 12
yes
yes
11 MAXIMUM APPLICATION RATING
B 125 DC
C 120/240 AC 2
D 240 AC
K 120 AC
F 277 AC
M 80 DC
12 AGENCY APPROVAL 11
A without approvals
F UL489 Listed, CSA Certified & VDE Certified
G UL489 Listed & CSA Certified
J UL489 Listed, CSA Certified & TUV Certified
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com

Share Link: 