DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

KAC-12 Ver la hoja de datos (PDF) - Unspecified

Número de pieza
componentes Descripción
Fabricante
KAC-12
ETC
Unspecified ETC
KAC-12 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
High Speed Fuses
North American — FWA 130V: 1000-4000A
FWA
Specifications
Description: North American
style flush-end high speed fuses.
Dimensions: See Dimensions
illustrations.
Ratings:
Volts: — 130Vac
Amps: — 1000-4000A
IR: — 200kA RMS Sym.
— 50kA @130Vdc
Agency Information: CE, UL Recognized on 1000-2000A
fuses
Electrical Characteristics
Total Clearing I2t
The total clearing I2t at
rated voltage and at power
factor of 15% are given in
1.5
K
1.0
the electrical characteris-
tics. For other voltages, the 0.5
clearing I2t is found by
multiplying by correction
0.3
factor, K, given as a func- 0.2
tion of applied working
voltage, Eg, (rms).
0.15
26
65
Eg
104 130
Dimensions (in)
Catalog Number
FWA-1000AH-2000AH
FWA-2500AH-3000AH
FWA-4000AH
Fig. B C D Thread Depth
1 2.0 1.0 — Tapped 38”-24 x 12
1 3.0 1.5 — Tapped 12”-20 x 12
2 3.5 1.5 1.5 Tapped 12”-20 x 12
1mm = 0.0394∑ / 1∑ = 25.4mm
Fig. 1: 1000-3000A
Fig. 2: 4000A
1.875
1.875
Arc Voltage
This curve gives the peak
UL
arc voltage, UL, which
may appear across the
300
fuse during its operation
as a function of the
200
applied working voltage,
Eg, (rms) at a power fac- 100
tor of 15%.
Eg
Power Losses
50
100
150
Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The correc-
1.0
0.8
Kp
0.6
0.5
0.4
0.3
tion factor, Kp, is given as 0.2
a function of the RMS load
current, Ib, in % of the
rated current.
0.1
Ib
30 40 50 60 70 80 90 100%
Catalog Numbers
Electrical Characteristics
I2t (A2 Sec)
Catalog
Rated Current
Clearing Watts
Numbers
RMS-Amps
Pre-arc at 130V Loss
FWA-1000AH
1000
170000 460000
60
FWA-1200AH
1200
270000 730000
70
FWA-1500AH
1500
520000 1400000
78
FWA-2000AH
2000
860000 2400000 108
FWA-2500AH
2500
1500000 4100000 130
FWA-3000AH
3000
2100000 5700000 150
FWA-4000AH
4000
3400000 9200000 257
• Watts loss provided at rated current.
• See accessories on page 106.
Features and Benefits
• Excellent dc performance
• Low arc voltage and low energy let-through (I2t)
• Low watts loss
• Superior cycling capability
Typical Applications
• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters
D
B
C
B
C
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
91