DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DU1P0-05S05 Ver la hoja de datos (PDF) - Astrodyne Corporation

Número de pieza
componentes Descripción
Fabricante
DU1P0-05S05 Datasheet PDF : 3 Pages
1 2 3
Isolated and Unregulated 1 WATT Modular DC/DC Converters
du1p0 series
INPUT SPECIFICATIONS
Input Voltage Ranges:
Input Current
Input Filter
ENVIRONMENTAL SPECIFICATIONS
5 VDC Nominal
4.5-5.5 VDC
12 VDC Nominal 10.8-13.2 VDC
15 VDC Nominal 13.5-16.5 VDC
24 VDC Nominal 21.6-26.4 VDC
(Nom Vin, Full Load)
See Selection Chart
Capacitor
Oper. Temperature
Storage Temperature
Relative Humidity
MTBF (Note 2)
Thermal Shock
Vibration
-25 to +85°C(See Derate Curve)
-55 to +105°C *
5% to 95% RH *
1.471 MHrs
MIL-STD-810D
10-55Hz, 10G, 30 Minutes
along X, Y, and Z
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation (Note 1)
20% - FL
Line Regulation (HL-LL)
Temperature Coefficient
Ripple/Noise(Single/Dual)
Voltage Accuracy
Short Circuit Protection
Minimum Load (Note 1)
Max. Load Capacitance
See Selection Chart
+/- 10% on 5V output
+/- 8% on all others
+/- 1.3%/1% of Vin
+/-0.1%/°C max.
100mV Pk-Pk, typ
+/-5%, max
1 Second max
10% of FL
Min Vin & Resitive Load
See Selection Chart
PHYSICAL SPECIFICATIONS
Dimensions
Case Material
Construction
Weight
0.77 x 0.24 x 0.40”
UL 94-V0 Non-Conductive
Black Plastic
Fully Encapsulated (UL94-V0)
2g (0.071oz)
NOTES
1) A Minimum 10% Load is required to maintain regulation
2) BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at
40°C. (Ground fixed and controlled environment)
GENERAL SPECIFICATIONS
Input-Out Isolation
Efficiency (Nom I/P & FL)
Switching Frequency
Isolation Resistance
Isolation Capacitance
Safety
1000VDC; (3000VDC suffix-N)
See Selection Chart
60Khz
10000 M Ohms
30pF, max.
UL, TUV, CB, CE
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.