DATA SHEET • AS186-302, AS186-302LF
IP3 vs. Voltage and Temperature
Control Voltage
(V)
3
3
3
5
5
5
Tone frequencies: 900 and 901 MHz.
Temperature
(°C)
-40
25
85
-40
25
85
IP3 @ 8 dBm
Each Tone (dBm)
44
38
29.5
47.5
46.5
45.5
Truth Table
V1
V2
0
VHIGH
VHIGH
0
All other conditions not recommended.
VHIGH = 3 V to 5 V.
J1–J2
Isolation
Insertion loss
J1–J3
Insertion loss
Isolation
MSOP-8 Exposed Pad
0.122 (3.09 mm) 0.0256
0.114 (2.89 mm) (0.650 mm)
8
Typ.
0.122
(3.09 mm)
0.114
(2.89 mm)
0.072 (1.83 mm)
0.062 (1.57 mm)
0.073
(1.85 mm)
0.063
(1.60 mm)
1
Pin 1
Indicator
0.200 (5.08 mm)
0.114 (4.67 mm)
Exposed
Paddle
0.012 (0.30 mm)
0.008 (0.20 mm)
0.044
(1.12 mm) Max.
0.006 (0.15 mm)
0.002 (0.05 mm)
Recommended Solder Reflow Profiles
Refer to the “Recommended Solder Reflow Profile”
Application Note.
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
Compression Point vs. Voltage
and Temperature @ 900 MHz
Control
Voltage
(V)
3
3
3
5
5
5
Frequency: 900 MHz.
Temperature
(°C)
-40
25
85
-40
25
85
Input Power
@ 1 dB
Compression
(dBm)
20.5
20
19
28.5
28
27.5
Input power
@ 0.1 dB
Compression
(dBm)
16.5
15.3
14
23
23
23
Absolute Maximum Ratings
Characteristic
Value
RF input power
Control voltage
1 W max. for f > 500 MHz
100 mW for f < 500 MHz
VCTL = 0/8 V
-0.2 V, +8 V
Operating temperature
-40 °C to +85 °C
Storage temperature
-65 °C to +150 °C
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce poten-
tials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.