SK1816
LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATINGS (TA=25°С)
PARAMETER
SYMBOL
RATINGS
UNIT
Supply Voltage
VCC
2.5~20
V
Supply Current
ICC
10
mA
Circuit Current
IO
20
mA
SIP-3
Power Dissipation
SOT-23
PD
400
mW
200
mW
Operating Temperature
TOPR
-30 ~ +125
°С
Storage Temperature
TSTG
-40 ~ +150
°С
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
ELECTRICAL CHARACTERISTICS (TA=25°С, unless otherwise specified.)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN TYP MAX UNIT
Low-Level Output Voltage
VOL
VCC = 16V, IOUT=12mA, B=30 mT
VCC =3.6V, IOUT=12mA, B=30 mT
0.2 0.7 V
0.3 0.7 V
Output Leakage Current
ILEAK VCC =16V, B=-30 mT
1 10 μA
Supply Current
ICC
VCC =16V
VCC =3.6V
6 10 mA
5.5 10 mA
Output Switching Time
MAGNETIC CHARACTERISTICS
TR VCC =16V, RL=10KΩ, CL=10pF
TF VCC =16V, RL=10KΩ, CL=10pF
5 μS
1 μS
Operate Point
BOP At TA=25°С
5 mT
Release Point
BRP At TA=25°С
-5 mT
Hysteresis
BHYS At TA=25°С
5.5 10 mT
Note: 1. BOP=operate point (output turns ON); BRP =release point (output turns OFF); BHYS =hysteresis(BOP – BRP).
As used here, negative flux densities are defined as less than zero (algebraic convention). Typical values
are at TA=25°С and VCC =12V.
2. 1mT=10 gauss
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 8
QW-R118-004,H