60W Single Output LED Power Supply
PLC-60 series
Features :
Universal AC input / Full range
High efficiency up to 89%
Adjustable output voltage and current level
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Fully isolated plastic case with terminal block style of I/O
Built-in active PFC function, comply with EN61000-3-2 class C
(75% load)
Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
2 years warranty
SPECIFICATION
LPS F
110
M
M SELV
( for 48V only)
..
( except for 48V )
MODEL
PLC-60-12
PLC-60-15
PLC-60-20
PLC-60-24
PLC-60-27
PLC-60-36
PLC-60-48
DC VOLTAGE
12V
CONSTANT CURRENT REGION Note.6 8.4 ~ 12V
RATED CURRENT
5A
15V
10.5 ~15V
4A
20V
14 ~ 20V
3A
24V
16.8 ~24V
2.5A
27V
18.9 ~27V
2.3A
36V
25.2 ~ 36V
1.7A
48V
33.6 ~ 48V
1.3A
OUTPUT
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
RATED POWER
60W
60W
60W
RIPPLE & NOISE (max.) Note.2 2Vp-p
2.4Vp-p
1.8Vp-p
VOLTAGE ADJ. RANGE Note.5 11.5 ~ 13V
14.5 ~ 16.2V 19.5 ~ 22V
CURRENT ADJ. RANGE Note.5 3.75 ~ 5.15A 3 ~ 4.12A
2.25 ~ 3.09A
VOLTAGE TOLERANCE Note.3 ±10%
LINE REGULATION
±3.0%
LOAD REGULATION
±5.0%
SETUP TIME
500ms / 230VAC 3000ms / 115VAC at full load
0 ~ 2.5A
60W
2.4Vp-p
24 ~ 26V
1.875 ~ 2.575A
0 ~ 2.3A
62.1W
2.7Vp-p
25 ~ 30V
1.725 ~ 2.369A
0 ~ 1.7A
61.2W
3.6Vp-p
32.5 ~ 39V
1.275 ~ 1.751A
0 ~ 1.3A
62.4W
4.6Vp-p
43.6 ~ 51.8V
0.975 ~ 1.339A
VOLTAGE RANGE Note.4 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
127 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.92/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading75% at 115VAC/230VAC input
INPUT EFFICIENCY (Typ.)
85%
86%
87.5%
87%
88%
89%
89%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.8A/115VAC 0.4A/230VAC
COLD START 35A(twidth=35μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION OVER VOLTAGE
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
13.8 ~ 16V
17.5 ~ 21V
23 ~ 26V
28 ~ 32V
31 ~ 35V
41 ~ 46V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 60V
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-30 ~ +50(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
±0.03%/(0 ~ 50)
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL1310, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
EMC IMMUNITY
MTBF
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A
515Khrs min. MIL-HDBK-217F (25)
OTHERS
NOTE
DIMENSION
181.5*62*35mm (L*W*H)
PACKING
0.41Kg; 30pcs/13.3Kg/0.67CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Please refer to "DRIVING METHODS OF LED MODULE".
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.