AD707–SPECIFICATIONS (@ +25؇C and ؎15 V, unless otherwise noted)
Conditions
AD707J/A
AD707K/B
Min Typ Max Min Typ Max
Units
INPUT OFFSET VOLTAGE
Initial
vs. Temperature
Long-Term Stability
Adjustment Range
TMIN to TMAX
R2 = 20 k(Figure 19)
30 90
0.3 1.0
50 100
0.3
±4
10 25
0.1 0.3
15 45
0.3
±4
µV
µV/°C
µV
µV/month
mV
INPUT BIAS CURRENT
Average Drift
TMIN to TMAX
1.0 2.5
2.0 4.0
15 40
0.5 2.0
1.5 4.0
15 40/40/40
nA
nA
pA/°C
OFFSET CURRENT
VCM = 0 V
0.5 2.0
0.3 1.5
nA
OBSOLETE Average Drift
INPUT VOLTAGE NOISE
INPUT CURRENT NOISE
COMMON-MODE
REJECTION RATIO
OPEN-LOOP GAIN
TMIN to TMAX
0.1 Hz to 10 Hz
f = 10 Hz
f = 100 Hz
f = 1 kHz
0.1 Hz to 10 Hz
f = 10 Hz
f = 100 Hz
f = 1 kHz
VCM = ± 13 V
TMIN to TMAX
VO = ± 10 V
RLOAD 2 k
2.0 4.0
2 40
0.23 0.6
10.3 28
10.0 13.0
9.6 11.0
14 35
0.32 0.9
0.14 0.27
0.12 0.18
1.0 2.0
1 25/25/35
0.23 0.6
10.3 18
10.0 12
9.6 11.0
14 30
0.32 0.8
0.14 0.23
0.12 0.17
nA
pA/°C
µV p-p
nV/Hz
nV/Hz
nV/Hz
pA p-p
pA/Hz
pA/Hz
pA/Hz
120 140
130 140
dB
120 140
120 140
dB
3 13
5 13
V/µV
TMIN to TMAX
3 13
3 13
V/µV
POWER SUPPLY
REJECTION RATIO
VS = ± 3 V to ± 18 V
110 130
115 130
dB
TMIN to TMAX
110 130
110 130
dB
FREQUENCY RESPONSE
Closed-Loop Bandwidth
Slew Rate
0.4 0.9
0.12 0.3
0.4 0.9
0.12 0.3
MHz
V/µs
INPUT RESISTANCE
Differential
Common Mode
24 100
45 200
M
200
300
G
OUTPUT CHARACTERISTICS
Voltage
RLOAD 10 k
13.5 14
13.5 14
±V
RLOAD 2 k
12.5 13.0
12.5 13.0
±V
RLOAD 1 k
12.0 12.5
12.0 12.5
±V
RLOAD 2 k
TMIN to TMAX
12.0 13.0
12.0 13.0
±V
OPEN-LOOP OUTPUT
RESISTANCE
60
60
POWER SUPPLY
Current, Quiescent
Power Consumption, No Load
VS = ± 15 V
VS = ± 3 V
2.5 3
75 90
7.5 9.0
2.5 3
mA
75 90
mW
7.5 9.0
mW
NOTES
All min and max specifications are guaranteed. Specifications in boldface are tested on all production units at final electrical test. Results from those tests are used to
calculate outgoing quality levels.
Specifications subject to change without notice.
–2–
REV. B