OM185SM/SR/NR - OM186SM/SR/NR
3.5
ELECTRICAL CHARACTERISTICS (TJ = -55°C to +125°C)
Parameter
Conditions
Min.
Reference Voltage
Line Regulation
Load Regulation
IOUT = 10mA, Tj = 25°C
(VIN - VOUT) = 3V
10mA ≤ IOUT ≤ IFULL LOAD
1.5V ≤ (VIN - VOUT) ≤ 25 V (Note 3)
ILOAD = 10mA, 1.5V ≤ (VIN -VOUT) ≤ 15V, Tj = 25°C
15V ≤ (VIN - VOUT ) ≤ 35V (Notes 1 & 2)
(VIN - VOUT) = 3V
10mA ≤ IOUT ≤ IFULL LOAD
Tj = 25°C (Notes 1, 2, & 3)
1.238
1.220
Dropout Voltage
∆VREF = 1%, IOUT = IFULL LOAD
Current Limit
OM185SM
OM186SM
Minimum Load Current
Thermal Regulation
OM185SM
(VIN - VOUT) = 5V
(VIN - VOUT) = 25V
(VIN - VOUT) = 5V
(VIN - VOUT ) = 25V
(VIN - VOUT) = 25V
TA = 25°C, 30 ms pulse
2.0
0.10
1.0
0.05
OM186SM
Ripple Rejection
f = 120Hz
Adjust Pin Current
Adjust Pin Current Change
Temperature Stability
Long Term Stability
CADJ = 25µF Tantalum
IOUT - IFULL LOAD (VIN - VOUT) = 3V
TJ = 25°C
10mA ≤ IOUT ≤ IFULL LOAD
1.5V ≤ (VIN - VOUT) ≤ 25V
-55°C ≤ TJ ≤ +150°C
TA = 125°C, 1000 Hrs.
60
Max.
1.262
1.270
0.25
0.6
1.0
1.2
1.5
15
0.025
0.055
120
5
1
1
Units
V
V
%
%
%
%
V
A
A
A
A
mA
%/W
%/W
dB
µA
µA
%
%
Note 1: Load and line regulation are measured at a constant junction temperature by low duty cycle pulse testing.
Note 2: Line and load regulation are guaranteed up to the maximum power dissipation (OM185/20W, OM186/10W).
Power dissipation is determined by the input/output differential and the output current. Guaranteed maximum
power dissipation will not be available over the full input/output voltage range.
Note 3: IFULL LOAD curve is defined as the minimum value of current limit as a function of input to output voltage. Note that
power dissipation is only achievable over a limited range of input to output voltage.
Note 4: Dropout voltage is specified over the full output current range of the device.
The denotes the specifications which apply over the full operating temperature range.