DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HCPL-2602-500 Ver la hoja de datos (PDF) - HP => Agilent Technologies

Número de pieza
componentes Descripción
Fabricante
HCPL-2602-500
HP
HP => Agilent Technologies HP
HCPL-2602-500 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Switching Specifications
Over recommended temperature (TA = 0°C to +70°C), VCC = 5 V, II = 7.5 mA, unless otherwise specified.
Parameter
Symbol Device Min. Typ.* Max. Units
Test Conditions
Fig. Note
Propagation Delay
Time to High Output
tPLH
Level
75
ns TA = 25°C
20 48
100 ns
6, 7, 8 3
Propagation Delay
Time to Low Output
tPHL
Level
Pulse Width
Distortion
|tPHL-tPLH|
75
ns TA = 25°C
25 50
6, 7, 8 4
100 ns
3.5 35 ns
RL = 350
CL = 15 pF
9 13
Propagation Delay
tPSK
40 ns
12,
Skew
13
Output Rise Time
tr
24
ns
12
(10-90%)
Output Fall Time
tf
10
ns
12
(90-10%)
Propagation Delay
tELH
Time of Enable from
VEH to VEL
Propagation Delay
tEHL
Time of Enable from
VEL to VEH
30
ns RL = 350 , CL = 15 pF,
VEL = 0 V, VEH = 3 V
10, 11 5
20
ns RL = 350 , CL = 15 pF,
VEL = 0 V, VEH = 3 V
10, 11 6
Common Mode
Transient
Immunity at High
Output Level
|CMH|
HCPL-2602 1000 10,000
HCPL-2612 3500 15,000
V/µs
VCM = 50 V
VCM = 300 V
VO(MIN) = 2 V,
RL = 350 Ω,
II = 0 mA,
TA = 25°C
13 7, 9,
10
Common Mode
Transient
Immunity at Low
Output Level
|CML|
HCPL-2602 1000 10,000
HCPL-2612 3500 15,000
VCM = 50 V VO(MAX) = 0.8 V,
V/µs
RL = 350 Ω,
13 8, 9
VCM = 300 V II = 7.5 mA,
10
TA = 25°C
*All typicals at VCC = 5 V, TA = 25°C.
Package Characteristics
All Typicals at TA = 25°C
Parameter
Input-Output Momentary
Withstand Voltage*
Input-Output Resistance
Input-Output Capacitance
Sym. Min. Typ. Max. Units Test Conditions
Fig. Note
VISO 2500
RI-O
1012
V rms
RH 50%, t = 1 min.,
TA = 25°C
VI-O = 500 Vdc
2, 11
2
CI-O
0.6
pF f = 1 MHz
2
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable),
your equipment level safety specification or HP Application Note 1074 entitled “Optocoupler Input-Output Endurance Voltage.”
1-321