DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TEL3-0523NP Ver la hoja de datos (PDF) - Traco Power

Número de pieza
componentes Descripción
Fabricante
TEL3-0523NP
Traco
Traco Power Traco
TEL3-0523NP Datasheet PDF : 3 Pages
1 2 3
DC/DC Converters
TEL 3 Series
3 Watt
Input Specifications
Input current (no load)
5 Vin models
12 Vin models
20 Vin models
24 Vin models
48 Vin models
40 mA typ.
20 mA typ.
15 mA typ.
5 mA typ.
3 mA typ.
Input current (full load)
5 Vin models
12 Vin models
20 Vin models
24 Vin models
48 Vin models
820 mA typ.
320 mA typ.
190 mA typ.
155 mA typ.
80 mA typ.
Surge voltage (1 sec. max.)
5 Vin models
12 Vin models
20 Vin models
24 Vin models
48 Vin models
11 VDC
25 VDC
50 VDC
50 VDC
100 VDC
Reverse voltage protection 1.0 A max.
Output Specifications
Voltage set accuracy ±1 %
Regulation
– Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 10 – 100 %
single output models 0.5 % max.
dual output models balanced load 1.0 % max.
dual output models unbalanced load 2.0 % max
Ripple and noise (20 MHz Bandwidth) <60 mVpk-pk typ.
Temperature coefficient ±0.02 %/°K
Output current limitation >110 % Iout max., constant current
Short circuit protection indefinite (automatic recovery)
Capacitive load
single output models 2000 µF max.
dual output models 1000 µF max.
General Specifications
Temperature ranges
– Operating –40°C to +85°C
– Case +95°C max.
– Storage –40°C to +125°C
Load derating 3.3 %/K above 70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >1 Mio. h
Isolation voltage (60 sec.) – Input/Output/Case 1500 VDC
Isolation capacitance
– Input/Output 500 pF typ
Isolation resistance
– Input/Output (500 VDC) >1‘000 M Ohm
Switching frequency 300 kHz typ. (Pulse frequency modulation PFM)
Safety standards UL 60950-1, IEC/EN 60950-1
Compliance up to 60 VDC input voltage
(SELV limit)
Safety approvals CSA File No. 226037 (-NP models pending)
http://directories.csa-international.org
Environmental compliance – Reach www.tracopower.com/products/tel3-reach.pdf
– RoHS RoHS directive 2011/65/EU
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3

Share Link: 