DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SQ60120QPA28PKS Ver la hoja de datos (PDF) - SynQor Worldwide Headquarters

Número de pieza
componentes Descripción
Fabricante
SQ60120QPA28PKS
SYNQOR
SynQor Worldwide Headquarters SYNQOR
SQ60120QPA28PKS Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Technical Specification
Input: 36-75 V
Output: 12 V
Current: 28 A
Package: Quarter-brick
ELECTRICAL CHARACTERISTICS (Continued)
Parameter P
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control (Option P)
Off-State Voltage
On-State Voltage
ON/OFF Control (Option N)
Off-State Voltage
On-State Voltage
Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
Min.
260
-1.0
2.4
2.4
-1.0
140
Typ.
300
16
10
2.6
2.1
Max. Units Notes & Conditions
340
kHz
Figure B
0.8
V
18
V
Figure B
18
V
0.8
V
V Over full temp range; no load
150
°C Average PCB Temperature
°C
106 Hrs.
106 Hrs.
106 Hrs.
TMSReI-LeN-HW oDuBTr-K0w-02e01b37s3iFt;e28;fo08r%0d%leoltaoadail,ds3,30000LLFFMM,,4400ooCCTTaa
Standards Compliance and Qualification Testing
Parameter P
STANDARDS COMPLIANCE
UL/cUL 60950-1
EN60950-1
72/23/EEC
93/68/EEC
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Notes
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP (Normal Performance)
Section 7 - electrical safety, Section 9 - bonding/grounding
An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety
certificates on new releases or download from the SynQor website.
Parameter P
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units Test Conditions
32
5
5
10
5
5
5
15 pins
95% rated Vin and load, units at derating point, 1000 hours
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003 and JESD22-B102D
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we
supply robust, reliable product. Contact the factory for official product family qualification documents.
Product # SQ60120QPA28
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2SQ612J Rev. B
06/17/09
Page 4

Share Link: 