DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PA2011 Ver la hoja de datos (PDF) - ProTek Devices.

Número de pieza
componentes Descripción
Fabricante
PA2011
Protek-Devices
ProTek Devices. Protek-Devices
PA2011 Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
PA2011
ANALOG PRODUCTS DIVISION
Low RDSON SPDT Analog Switch.
Specifications V+ = 3.0V Test Conditions unless otherwise specified: V+ = 3.0V±10%, VIN = 0.4 V or 2.0V
Parameter
Symbol Test Conditions
Temp Min Typ Max Unit
Analog Switch
Analog Signal Range
On-Resistance
RON Matching
VNO,VNC,
VCOM
RON
RON
VCC = 2.7V, VCOM = 0.9V- 1.5V
INO , INC = 50mA,
Full
0.0
Room
Full
1.8
VCC
V
2.7
2.9
0.2
RON Flatness
RON(FLAT)
0.2
0.5
Switch Off Leakage
Current
Channel On
Leakage Current
IOFF(NO) or
IOFF(NC)
ICOM(OFF)
ICOM(ON)
V+ = 3.3 V,
VNO, VNC= 1.0 V/3.0 V, VCOM = 3.0 V/1.0 V
V+ = 3.3 V, VNO, VNC = VCOM = 1.0V/3.0 V
Room
-1
Full
-10
Room
-1
Full
-10
Room
-1
Full
-10
Digital Control
Input High Voltage
Input Low Voltage
Input Capacitance
Input Current
VINH
VINL
Cin
IINL or IINH
VIN = 0 or V+
Full
1.5
Full
Full
4
Full
1
Dynamic Characteristics
Turn On Time
tON
Room
Full
45
Turn Off Time
tOFF
VNO or VNC = 2.0 V, RL = 300 , CL = 35 pF
Room
Full
29
Break Before Make
Time
tBBM
Room
Full
16
Charge Injection
QINJ
CL = 1 nF, VGEN = 0 V, RGEN = 0
Room
2
-1
-10
-1
-10
nA
-1
-10
VnA
0.4
pF
1
µA
75
77
59
62
nS
pC
Off Isolation
OIRR
Room
-62
RL = 50 , CL = 5 pF, f = 1 MHz
dB
Crosstalk
XTALK
Room
-69
NO, NC OFF
Capacitance
Chanel On
Capacitance
CNO(off)
CNC(off)
CON
VIN = 0 or V+, f = 1 MHz
Room
28
pF
Room
84
Power Supply
Positive Supply
Range
Negative Supply
Current
V+
VIN = 0 or V+
I+
1.8
0.01
3.3
V
1.0
µA
Notes:
1. Room = 25 °C, Full = as determined by the operating suffix.
2. Typical values are for design aid only, not guaranteed nor subject to production testing.
3. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
4. Guarantee by design, not subjected to production test.
5. VIN = input voltage to perform proper function.
6. Guaranteed by 5 V leakage testing, not production tested.
3
561 E. Elliot Road #175 Chandler, AZ 85225 Tel: (480) 539-2900. Fax: (602) 431-2288
95040 Rev.3. 10/11
www.protekanalog.com
NOT FOR USE IN LIFE SUPPORT SYSTEMS

Share Link: 