DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MBM29LV008BA Ver la hoja de datos (PDF) - Spansion Inc.

Número de pieza
componentes Descripción
Fabricante
MBM29LV008BA
Spansion
Spansion Inc. Spansion
MBM29LV008BA Datasheet PDF : 51 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MBM29LV008TA/BA-70/90
MBM29LV008TA/008BA Standard Command Definitions
Command
Sequence
Bus
Write
Cycles
First Bus Second Bus Third Bus
Write Cycle Write Cycle Write Cycle
Fourth Bus
Read/Write
Cycle
Fifth Bus
Write Cycle
Sixth Bus
Write Cycle
Req’d Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data
Read/Reset
1 XXXh F0h — — — — — — — — — —
Read/Reset
3 555h AAh 2AAh 55h 555h F0h RA* RD* — — — —
Autoselect
3 555h AAh 2AAh 55h 555h 90h IA* ID* — — — —
Program
4 555h AAh 2AAh 55h 555h A0h PA PD — — — —
Chip Erase
6 555h AAh 2AAh 55h 555h 80h 555h AAh 2AAh 55h 555h 10h
Sector Erase
6 555h AAh 2AAh 55h 555h 80h 555h AAh 2AAh 55h SA 30h
Sector Erase Suspend Erase can be suspended during sector erase with Addr. (“H” or “L”). Data (B0h)
Sector Erase Resume Erase can be resumed after suspend with Addr. (“H” or “L”). Data (30h)
* : The fourth bus cycle is only for read.
Notes: Address bits A19 to A11 = X = “H” or “L” for all address commands except or Program Address (PA) and
Sector Address (SA)
Bus operations are defined in “MBM29LV008TA/008BA User Bus Operations”.
RA = Address of the memory location to be read
IA = Autoselect read address that sets A10, A6, A1, A0.
PA = Address of the memory location to be programmed
Addresses are latched on the falling edge of the write pulse.
SA = Address of the sector to be erased. The combination of A19, A18, A17, A16, A15, A14, and A13 will
uniquely select any sector.
RD = Data read from location RA during read operation.
ID = Device code / manufacture code for the address located by IA.
PD = Data to be programmed at location PA. Data is latched on the rising edge of write pulse.
Both Read/Reset commands are functionally equivalent, resetting the device to the read mode.
Command combinations not described in Standard Command Definitions table are illegal.