DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

JQ1P-18V Ver la hoja de datos (PDF) - Matsushita Electric Works

Número de pieza
componentes Descripción
Fabricante
JQ1P-18V
Nais
Matsushita Electric Works Nais
JQ1P-18V Datasheet PDF : 5 Pages
1 2 3 4 5
JQ
3-(1). Coil temperature rise
(1 Form A type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
50
40
5 A at 70°C
5 A at 85°C
30
20
3 A at 70°C
3 A at 85°C
10
0 100 110 120 130 140 150 160 170 180 190
Coil applied voltage, %V
4-(1). Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1a-24V
Contact carrying current: 3 A, 5 A
400
300
1
2
200
3
56
4
100
7
0 20 30 40 50 60 70 80 90
Ambient temperature, °C
High capacity type
1-(1). Operate & release time
(1 Form A type)
Tested sample: JQ1aP-12V, 25 pcs.
8
6
Operate time
4
Max.
Min.
Max.
2
Min.
Release time
0
80
100 120
150
Coil applied voltage, %V
3-(1). Coil temperature rise
(1 Form A type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
70
60
10 A at 85°C
50
10 A at 70°C
40
30
5 A at 70°C
5 A at 85°C
20
10
0 100
120 140 160 180
Coil applied voltage, %V
74
3-(2). Coil temperature rise
(1 Form C type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
70
60
5 A at 70°C
50
3 A at 70°C
40
5 A at 85°C
30
3 A at 85°C
20
10
0
100 110 120 130 140 150 160
Coil applied voltage, %V
4-(2). Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1-24V
Contact carrying current: 3 A, 5 A
400
300
1
2
200
5
3
4
100
6
7
0 20 30 40 50 60 70 80 90
Ambient temperature, °C
1-(2). Operate & release time
(1 Form C type)
Tested sample: JQ1P-12V, 25 pcs.
8
6
Operate time
4
Max.
Max.
2
Min.
Min.
Release time
0 80
100 120
150
Coil applied voltage, %V
3-(2). Coil temperature rise
(1 Form C type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
70
10 A at 85°C
60
10 A at 70°C
50
40
5 A at 70°C
5 A at 85°C
30
20
10
0 100 110 120 130 140 150 160
Coil applied voltage, %V
1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 3 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 3 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 3 A)
7 Pick-up voltage
2. Life curve
Ambient temperature: room temperature
100
125V AC resistive load
10
250V AC resistive load
1
0
2
4
6
8
10
Contact current, A

Share Link: 