DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HY10-P Ver la hoja de datos (PDF) - LEM Industrial

Número de pieza
componentes Descripción
Fabricante
HY10-P
LEM
LEM Industrial LEM
HY10-P Datasheet PDF : 2 Pages
1 2
Current Transducers HY 5 to 25-P
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
IPN = 5 .. 25 A
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
5
± 15
10
± 30
12.5
± 37.5
15
± 45
20
± 60
25
± 75
Primary
conductor
(mm)
0.7
1.1
1.4
1.4
2 x 1.2 1)
2 x 1.4 1)
VC
IC
ÎP
Vd
Vb
R IS
VOUT
ROUT
RL
Supply voltage (± 5 %) 6)
Current consumption
Overload capability (1 ms)
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn
R.m.s. rated voltage, safe separation
Isolation resistance @ 500 VDC
Output voltage @ ± IPN, RL = 10 k, TA = 25°C
Output internal resistance
Load resistance
Accuracy - Dynamic performance data
X
εL
V
OE
VOH
V
OT
ε TC G
tr
di/dt
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity 3) (0 .. ± IPN)
Electrical offset voltage, T = 25°C
A
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN
Thermal drift of V
OE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
di/dt accurately followed
Frequency bandwidth 4) (- 3 dB)
typ.
max.
General data
T
Ambient operating temperature
A
T
Ambient storage temperature
S
m
Mass
Standards 5)
Type
HY 5-P
HY 10-P
HY 12-P
HY 15-P
HY 20-P
HY 25-P
±12 .. ±15 V
±10
mA
50 x IPN
2.5
kV
5002)
V
> 1000 M
±4
V
100
>1
k
< ±1
%
< ±1 % of IPN
< ±40
mV
< ±15
±1.5
±3
< ±0.1
<3
> 50
DC .. 50
mV
mV/K
mV/K
%/K
µs
A/µs
kHz
-10 .. +80 °C
-25 .. +85 °C
< 14
g
EN 50178
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 2500 V~
Compact design for PCB mounting
Low power consumption
Extended measuring range (3 x IPN)
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Easy mounting
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Applications
General purpose inverters
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS).
Notes : 1) Conductor terminals are soldered together.
2) Pollution class 2, overvoltage category III.
3) Linearity data exclude the electrical offset.
4) Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency.
5) Please consult characterisation report for more technical details and
application advice.
6) Operating at ±12V Vc < ±15V will reduce measuring range.
LEM Components
030402/4
www.lem.com

Share Link: 