DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

WL-1A100P1 Ver la hoja de datos (PDF) - OMRON Corporation

Número de pieza
componentes Descripción
Fabricante
WL-1A100P1
Omron
OMRON Corporation Omron
WL-1A100P1 Datasheet PDF : 23 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Specifications
D4C
Approved Standards
Agency
TÜV Product
Service
UL
CSA
CCC(CQC)
Standard
EN60947-5-1
UL508
CSA C22.2 No.14
GB14048.5
File No.
*1, 3
E76675 *2
LR45746 *2
2003010305077626 *3
*1. Models with VCTF oil-resistant cables and pre-wired models only.
(Applicable only to standard models listed on pages 2 to 4.)
*2. SJT(O)-cable models only.
(Applicable only to standard models listed on pages 2 to 3.)
*3. Ask your OMRON representative for information on approved models.
Ratings
Standard Model
Rated voltage
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Non-inductive load (A)
Resistive load
Lamp load
NC
NO
NC
NO
5 (0.1)
5
1.5
0.7
1
0.5
5 (0.1)
2
5 (0.1)
2
4 (0.1)
2
0.4
0.05
0.2
0.03
Pre-wired Model
Rated voltage
125 VAC
30 VDC
Non-inductive load(A)
Resistive load
Lamp load
NC
NO
NC
NO
1
1
1
0.7
1
1
1
1
Inductive load (A)
Inductive load
Motor load
NC
NO
NC
NO
3
2.5
1.3
2
1.5
0.8
5
4
3
4
4
3
3
3
3
0.4
0.05
0.2
0.03
Inductive load(A)
Inductive load
Motor load
NC
NO
NC
NO
1
1
1
1
1
1
1
1
Inrush NC 20 A max.
current NO 10 A max.
Note: 1. The values given on the left are steady-state
currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times
the steady-state current.
4. Motor loads have an inrush current of 6 times
the steady-state current.
5. The values "0.1" given in parentheses are for
micro load models.
Approved Standard Ratings
TÜV(EN60947-5-1),CCC(GB14048.5)
Model
D4C-1@@@
D4C-2@@@
D4C-3@@@
D4C-4@@@
D4C-5@@@
D4C-6@@@
Applicable category and
ratings
AC-15 2 A/250 V
DC-12 2 A/30 V
AC-15 2 A/125 V
DC-12 2 A/30 V
AC-14 0.1 A/125 V
DC-12 0.1 A/30 V
AC-14 0.1 A/125 V
DC-12 0.1 A/30 V
UL/CSA
B300 (D4C-16@@, -17@@)
B150 (D4C-26@@, -27@@)
B300
Rated voltage Carry current
120 VAC
240 VAC
5A
Current(A)
Make Break
30
3
15
1.5
B150
Rated voltage Carry current
120 VAC
5A
Current(A)
Make Break
30
3
I the
5A
4A
5A
4A
0.5 A
0.5 A
0.5 A
0.5 A
Volt-amperes(VA)
Make
Break
3,600
360
3,600
360
Volt-amperes(VA)
Make
Break
3,600
360
Characteristics
Degree of protection
Durability Mechanical *3
*1 Electrical *2
Operating speed
Operating Mechanical
frequency Electrical
Rated frequency
Insulation resistance
Contact resistance (initial)
Between terminals of
the same polarity
Between current-
Dielectric carrying metal
strength part and ground
Between each terminal
and non-current-carry-
ing metal part,
Rated insulation voltage (Ui)
Pollution degree (operating environment)
Short-circuit protective device (SCPD)
Conditional short-circuit current
Conventional enclosed
thermal current (I the)
Protection against electric shock
Vibration re-
sistance
Malfunction
Shock re- Destruction
sistance Malfunction
Ambient operating temperature
Ambient operating humidity
Weight (D4C-1202)
IP67
10,000,000 operations min.
200,000 operations min. (5 A at 125 VAC, resistive load)
0.1 mm/s to 0.5 m/s (in case of plunger)
1 mm/s to 1 m/s (in case of roller lever)
120 operations/min
30 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
250 mΩ max. (initial value with 2-m VCTF cable)
300 mΩ max. (initial value with 3-m VCTF cable)
400 mΩ max. (initial value with 5-m VCTF cable)
1,000 VAC,50/60 Hz for 1 min
1,500 VAC,50/60 Hz for 1 min
Uimp: 2.5 kV(EN60947-5-1)
1,500 VAC,50/60 Hz for 1 min
Uimp: 2.5 kV(EN60947-5-1)
300 V (EN60947-5-1) *5
3 (EN60947-5-1)
10 A fuse type gI or gG (IEC60269)
100 A (EN60947-5-1)
5 A, 4 A, 0.5 A (EN60947-5-1)
Class I (with grounding wire) *6
10 to 55 Hz, 1.5-mm double amplitude *4
1,000 m/s2 min.
500 m/s2 min. *4
-10°C to +70°C (with no icing)
35% to 95%RH
With 3-m VCTF cable: 360 g
With 5-m VCTF cable: 540 g
Note: The above figures are initial values.
*1. The values are calculated at an operating temperature of +5°C to +35°C,
and an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating
environments.
*2. Pre-wired Models: 1,000,000 operations min. (DC specifications, switching
current: 0.1 A)
*3. Outdoor specifications: 500,000 operations min.
*4. Excluding Plastic Rods.
*5. Pre-wired models: 250 V
*6. Pre-wired models: class III
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
6