High-attenuation type of common mode noise from 150kHz to 1MHz (2-stage filter)
NBC series
Ordering information
NBC -10 -472 -O
1
2
3
4
1Model Name
2Rated Current
3Line to ground capacitor code:See table 1.1.
DIN rail installation type is option
The terminal cover is retracted inside the unit
table1.1 Line to ground capacitor code
Code
Leakage Current Line to ground
(Input 125/250V 60Hz)
capacitor
(nominal value)
681 75.5 A/ 150 A max
680pF
102 0.13mA/ 0.25mA max
1000pF
222 0.25mA/ 0.5 mA max
2200pF
332 0.38mA/ 0.75mA max
3300pF
472 0.5 mA/ 1.0 mA max
4700pF
*When the line to ground capacitor code is
different, the attenuation characteristic is
different.
4Options
D :DIN rail installation type
* The dimensions change when the option is set.
Refer to External view.
Features of NBC series
High-attenuation type of common mode noise from 150kHz to 1MHz (2-stage filter)
- Single Phase 250 VAC
- Quick and easy push-down terminal
Just connect the wires, push down and tighten
the screws with a screwdriver
Specifications
No. Items
1 Rated Voltage[V]
2 Rated Current[A]
3 Test Voltage (Terminal-Mounting Plate)
4 Isolation Resistance (Terminal-Mounting Plate)
5 Leakage current 125/250V 60Hz
6 Voltage drop
7 Safety agency approval temperatures
8 Operating temperature
9 Operating humidity
10 Storage temperature/humidity
11 Vibration
12 Impact
13 Safety agency approvals
14 Case size (without projection) /Mass
NBC-06-472
NBC-10-472
AC 1f 250 / DC250
NBC-16-472
NBC-20-472
NBC-30-472
6
10
16
20
30
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
500 VDC 100MW min at room temperature and humidity
0.5mA/1.0mA max
1.0V max
-25 to +85C (Refer to Derating Curve)
-40 to +85C (Refer to Derating Curve)
20 to 95%RH (Non condensing)
-40 to +85C/20 to 95%RH (Non condensing)
10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis
196.1m/s2 (20G), 11ms Once each X, Y and Z axis
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
53X41X92 mm (WXHXD) /270g max (Option : -D refer to external view)
Circuit Diagram
Case
1
LINE
Noise
2
Filter
3
CY
LOAD
CY
4
CY : Line to ground capacitor
: Mounting Plate
I-4
Derating Curve
100
80
60
40
20
0
-40 -30 -20 40 50 55 60 70 80 90
Ambient Temperature [C]