VE SERIES
s SPECIFICATIONS
Contact
Coil
Time Value
Insulation
Life
Other
Item
VE-( ) HME-K
VE-( ) HM-K
VE-( ) HE-K
VE-( ) H-K
VE-( ) HM5-K
VE-( ) H5-K
Arrangement
1 form A (SPST-NO) 1 form C (SPDT) 1 form A (SPST-NO) 1 form C (SPDT)
Material
Gold overlay silver alloy
Silver-cadmium oxide alloy
Style
Single
Resistance (initial) (at 1 A 6 VDC) Maximum 70 m(VE-HM, H)
Maximum 100 m(VE-HME, HE)
Maximum 200 m
Rating (resistive)
5 A 250 VAC
5 A 250 VAC (N.O.) 5 A 250 VAC
3 A 250 VAC (N.C.)
Maximum Carrying Current 7 A
Maximum Switching Power 1,250 VA
1,250 VA (N.O.) 1,250 VA
750 VA (N.C.)
Maximum Switching Voltage 250 VAC, 150 VDC
Maximum Switching Current 5 A
5 A (N.O.)
5A
3 A (N.C.)
Minimum Switching Load*1 10 mA, 5 VDC (VE-HM, H), 100 mA 5 VDC (VE-HME, HE, HM5, H5)
Nominal Power (at 20°C)
Standard type: 0.36 W. High sensitivity type: 0.25 W
Operate Power (at 20°C)
Standard type: 0.177 W. High sensitivity type: 0.13 W
Operating Temperature
Standard: –40°C to +85°C. High sensitivity: –40°C to +90°C (no frost)
Operate (at nominal voltage) Maximum 10 ms
Release (at nominal voltage) Maximum 5 ms
Resistance (at 500 VDC)
Minimum 1,000 M
Dielectric
Strength
between open
contacts
between coil
and contacts
1,000 VAC 1 minute 750 VAC 1 minute 1,000 VAC 1 minute 750 VAC 1 minute
2,000 VAC 1 minute
Surge Strength
Standard type: 4,000 V (at 2 × 10 µs)
High dielectric strength type: 6,000 V (at 2 × 10 µs)
Mechanical
1 × 107 operations minimum
Electrical (at Rating)
Standard Type: 1 × 105 ops. min. High sensitivity type: 5 × 104 ops. min.
Vibration Misoperation
Resistance
Endurance
10 to 55 Hz (double amplitude of 3.3 mm)
10 to 55 Hz (double amplitude of 3.3 mm)
Shock
Misoperation
Resistance
Endurance
100 m/s2 (11 ±1 ms)
500 m/s2 (6 ±1 ms)
Weight
Approximately 8 g
*1 Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual
load before production since reference values may vary according to switching frequencies, environmental conditions
and expected reliability levels.