DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MX7575D Ver la hoja de datos (PDF) - Maxim Integrated

Número de pieza
componentes Descripción
Fabricante
MX7575D Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
CMOS, µP-Compatible, 5µs/10µs, 8-Bit ADCs
Z-80
MREQ
RD
ADDRESS BUS
+5V
TP/MODE
EN
ADDRESS
DECODE
CS MX7575*
MX7576
RD
D7
D0
DB7
DB0
DATA BUS
* SOME CIRCUITRY OMITTED FOR CLARITY
Figure 7. MX7575/MX7576 to Z-80 ROM Interface
CS
t1
RD
t5
t4
UPDATE
LATCH
DEFER
UPDATING
BUSY
t3
HIGH-
DATA IMPEDANCE
BUS
VALID
DATA
t7
HIGH-IMPEDANCE BUS
VALID
DATA
HIGH-
IMPEDANCE
BUS
Figure 9. MX7576 Asynchronous Conversion Mode Timing
Diagram
PA2
PA0
TMS32010
MEN
DEN
DB7
DB0
ADDRESS BUS
+5V
TP/MODE
EN
ADDRESS
DECODE
CS MX7575*
MX7576
RD
D7
D0
DATA BUS
* SOME CIRCUITRY OMITTED FOR CLARITY
Figure 8. MX7575/MX7576 to TMS32010 ROM Interface
the µP, in that data can be accessed independently of
the clock. The output latches are normally updated on
the rising edge of BUSY. But if CS and RD are low
when BUSY goes high, the data latches are not updat-
ed until one of these inputs returns high. Additionally,
the MX7576 stops converting and BUSY stays high until
RD or CS goes high. This mode of operation allows a
simple interface to the µP.
Processor Interface for Signal Acquisition (MX7575)
In many applications, it is necessary to sample the
input signal at exactly equal intervals to minimize errors
due to sampling uncertainty or jitter. In order to achieve
this objective with the previously discussed interfaces,
the user must match software delays or count the num-
ber of elapsed clock cycles. This becomes difficult in
interrupt-driven systems where the uncertainty in inter-
rupt servicing delays is another complicating factor.
The solution is to use a real-time clock to control the
start of a conversion. This should be synchronous with
A0–A15
8085A
RD
ALE
AD0–AD7
ADDRESS BUS
ADDRESS
ENCODE
ADDRESS
LATCH
DATA BUS
MODE
CS MX7576*
RD
D0–D7
* SOME CIRCUITRY OMITTED FOR CLARITY
Figure 10. MX7576 to 8085A Asynchronous Conversion Mode
Interface
the CLK input to the ADC (both should be derived from
the same source), because the sampling instants occur
three clock cycles after CS and RD go low. Therefore,
the sampling instants occur at exactly equal intervals if
the conversions are started at equal intervals. In this
scheme, the output data is fed into a FIFO latch, which
allows the µP to access data at its own rate. This guar-
antees that data is not read from the ADC in the middle
of a conversion. If data is read from the ADC during a
conversion, the conversion in progress may be dis-
turbed, but the accessed data that belonged to the pre-
vious conversion will be correct.
The track/hold starts holding the input on the third
falling edge of the clock after CS and RD go low. If CS
and RD go low within 20ns of a falling clock edge, the
ADC may or may not consider this falling edge as the
first of the three edges that determine the sampling
instant. Therefore, the CS and RD should not be
allowed to go low within this period when sampling
accuracy is required.
_______________________________________________________________________________________ 7

Share Link: 