DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TOP222G-TL Ver la hoja de datos (PDF) - Power Integrations, Inc

Número de pieza
componentes Descripción
Fabricante
TOP222G-TL
Power-Integrations
Power Integrations, Inc Power-Integrations
TOP222G-TL Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
TOP221-227
D2
UF5401
L1
3.3 µH
+
R3
47 k
C1
2.2 nF
1 kV
D1
UF4005
Wide-Range
DC Input
-
T1
U1
D TOP221P
TOPSwitch-II
CONTROL
C
S
C2
330 µF
10 V
VR1
C3
100 µF
10 V
R2
100
D3
1N4148 R1
10
C4
100 µF
16 V
C5
47 µF
10 V
U2
PC817A
Figure 7. Schematic Diagram of a 4 W TOPSwitch-II Standby Power Supply using an 8 lead PDIP.
+5 V
RTN
+
12 V Non-Isolated
-
PI-2115-040401
Application Examples
Following are just two of the many possible TOPSwitch
implementations. Refer to the Data Book and Design Guide
for additional examples.
4 W Standby Supply using 8 Lead PDIP
Figure 7 shows a 4 W standby supply. This supply is used in
appliances where certain standby functions (e.g. real time
clock, remote control port) must be kept active even while the
main power supply is turned off.
The 5 V secondary is used to supply the standby function and
the 12 V non-isolated output is used to supply power for the
PWM controller of the main power supply and other primary
side functions.
For this application the input rectifiers and input filter are sized
for the main supply and are not shown. The input DC rail may
vary from 100 V to 380 V DC which corresponds to the full
universal AC input range. The TOP221 is packaged in an 8 pin
power DIP package.
The output voltage (5 V) is directly sensed by the Zener diode
(VR1) and the optocoupler (U2). The output voltage is determined
by the sum of the Zener voltage and the voltage drop across the
LED of the optocoupler (the voltage drop across R1 is negligible).
The output transistor of the optocoupler drives the CONTROL
pin of the TOP221. C5 bypasses the CONTROL pin and provides
control loop compensation and sets the auto-restart frequency.
The transformers leakage inductance voltage spikes are snubbed
by R3 and C1 through diode D1. The bias winding is rectified
and filtered by D3 and C4 providing a non-isolated 12 V output
which is also used to bias the collector of the optocouplers
output transistor. The isolated 5 V output winding is rectified by
D2 and filtered by C2, L1 and C3.
6
D
7/01

Share Link: 