DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LG1600FXH2433 Ver la hoja de datos (PDF) - Agere -> LSI Corporation

Número de pieza
componentes Descripción
Fabricante
LG1600FXH2433
Agere
Agere -> LSI Corporation Agere
LG1600FXH2433 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
LG1600FXH Clock and Data Regenerator
Data Sheet
August 1999
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent or latent damage to the device. These
are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in
excess of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect device reliability.
Table 2. Absolute Maximum Ratings
Parameter
Supply Voltage Range (VSS)
Loss of Signal Bias Voltage (VDD)
Power Dissipation
Voltage (all pins)
Transient Voltage to ac Couple Pins (V±IN, REXT)
Storage Temperature Range
Operating Temperature Range
Min
Max
Unit
–7
0.5
V
7
V
2
W
VSS
0.5
V
±3
V
–40
125
°C
–40
100
°C
Recommended Operating Conditions
Table 3. Recommended Operating Conditions
Parameter
Case Temperature
Power Supply
Symbol
tCASE
VSS
Min
0
–4.7
Max Unit
70
°C
–5.7
V
Handling Precautions
Although protection circuitry has been designed into this device, proper precautions should be taken to avoid expo-
sure to electrostatic discharge (ESD) during handling and mounting. Lucent Technologies Microelectronics Group
employs a human-body model (HBM) for ESD-susceptibility testing and protection design evaluation. The HBM
(resistance = 1500 , capacitance = 100 pF) is used. The HBM ESD threshold presented in Table 4 was obtained
by using these circuit parameters.
Table 4. ESD Threshold
HBM ESD Threshold
Device
Voltage
LG1600FXH
200 V
Mounting and Connections
Certain precautions must be taken when using solder. For installation using a constant temperature solder, temper-
atures of under 300 °C may be employed for periods of time up to 5 seconds, maximum. For installation with a sol-
dering iron (battery operated or nonswitching only), the soldering tip temperature should not be greater than
300 °C and the soldering time for each lead must not exceed 5 seconds.
8
Lucent Technologies Inc.

Share Link: 