3E Entry into Hold Over MTIE
Figure 8
10000
1000
GR-1244-C ORE , F ig. 5-8, P hase Transient
MTIE Masks for E ntry into Hold Over
E ntry in to Hold Over MTIE
100
10
1
0 .1
0 .0 1
0 .1
1
10
100
Ob servation T ime (sec)
1000
10000
3E 1µs Phase Transient MTIE
Figure 9
10000
GR-1244-CORE , Fig 5-9, M TIE m as k for I/O P hase Trans ient
1us P has e Trans ient M TIE
1000
100
10
1
0 .0 0 1
0 .0 1
0 .1
1
10
100
1000
10000
Obse rva tion Tim e (se c)
Preliminary Data Sheet #: TM012 Page 10 of 16 Rev: P06 Date: 05/20/ 02