SS311PT/SS411P
Table 1. SS311PT/SS411P Specifications (At 2.7 Vdc to 7 Vdc supply, 4 mA load, TA = -40 ºC to 150 ºC [-40 ºF to 302 ºF]
Characteristic
Condition
Minimum
Typical
Maximum
Unit
Supply voltage
-40 °C to 150 °C [-40 °F to 302 °F]
2.7
5.0
7.0
Vdc
Supply current
gauss <-140, Vs = 5 V, 25 °C [77°F]
-40 °C to 150 °C [-40 °F to 302 °F]
5.5
mA
14
Output current
4.0
mA
Vsat
gauss >140
0.4
V
Output leakage current
gauss <-140
10
µA
Output rise time
Output fall time
25 °C [77 °F]
1.5
µs
1.5
Thermal resistance:
SS311PT
303
°C/W
SS411P
233
Operate
-40 °C to 150 °C [-40 °F to 302 °F]
-30
55
140
gauss
Release
-40 °C to 150 °C [-40 °F to 302 °F]
-140
-55
30
gauss
Differential
-40 °C to 150 °C [-40 °F to 302 °F]
40
gauss
Operating temperature
-40 [-40]
150 [302]
°C [°F]
Storage temperature
-40 [-40]
150 [302]
°C [°F]
NOTICE
Bipolar Hall-effect sensors may have an initial output in either the ON or OFF state if powered up with an applied magnetic field in
the differential zone (applied magnetic field >Brp and <Bop). Honeywell recommends allowing 10 µs for output voltage to stabilize
after supply voltage has reached 5 Vdc.
Table 2. SS311PT/SS411P Absolute Maximum Ratings1
Characteristic
Minimum
Typical
Maximum
Unit
Supply voltage
-0.5
7.0
Vdc
Applied output voltage
-0.5
7.0
Vdc
Output current
8.0
mA
Magnetic flux
no limit
gauss
Note 1: The magnetic field strength (gauss) required to cause the switch to change state (operate and release) will be as specified
in the magnetic characteristics. To test the switch against the specified magnetic characteristics, the switch must be placed in a
uniform magnetic field.
NOTICE
Absolute maximum ratings are the extreme limits that the device will withstand without
damage to the device. However, the electrical and mechanical characteristics are not
guaranteed as the maximum limits (above recommended operating conditions) are
approached, nor will the device necessarily operate at absolute maximum ratings.